1 689 988 238
2012-11-06
|
Robert Bosch GmbH
Commissioning | ACS 651/751 | 89
en
4.
Enter the desired value and press
E.
"
The limit value for the maximum number of data records
is set.
i
If the number of stored data records exceeds the
limit value entered, vehicle A/C service can no longer
be performed. The vehicle A/C service can only be
performed again after transferring the data records
to a USB stick or by increasing the limit value (refer
to chapter 7.3.4 for procedure)
.
4.8.5
Compressor oil can size
1.
In the menu
System Defaults
, select "
Can Type
".
2.
Press
E
.
3.
Select the can type - fresh oil or UV dye.
4.
Select the required option.
i
Press
c
twice to return to the main menu.
"
The "
System Defaults
" are set.
4.9
Configuring the custom database
The ACS 651/751 contains a database, to which a
maximum of twenty vehicles can be added. The vehicle
code, vehicle model, year of make and the R134a
quantity for the vehicle can be entered at the work-
shop.
i
Refer to the vehicle documentation for the service
parameters.
1.
Connect the power cable to the mains supply.
2.
Turn on the master switch.
3.
In the main menu, select "
ACS Settings
" and press
E
.
The
Settings
menu is displayed.
4.
Select
"My Database"
and press
E
.
5.
Press .
The following screen is displayed.
i
The car code is automatically assigned.
i
In the "
R134a Qty
" field, the minimum quantity of
R134a that can be entered is 100 g.