Connections
3.1
Connecting the devices
Precondition: Install readers and other peripheral devices as
described in the corresponding technical documentation.
AC
N G
L1
BAT RTH
Power Supply
AMC2
DC
RS-485 EXT
T
---- OK ----
L N
+ -
+ -
+ -
C
DC BAT AC
1 2 3 4 5 6 7
1 2 3 4 5 6
1 2
2
1
Figure 3.1:
Connections in the enclosure
1.
Insert the cables of the device through the knock-outs at
the top-right side wall of the enclosure, or through the rear
of the enclosure.
2.
Provide an appropriate disconnect device to the supply
line.
!
Warning!
Risk of electric shock!
Disconnect the mains supply voltage before you work on the
devices inside the enclosure.