Thank you very much for purchasing our air conditioner. 
Please read this owner's manual carefully before using your air conditioner. 

Summary of Contents for ARC R-1 IR

Page 1: ...lation Manual X XXX XXX XXXX XX AIR CONDITIONER REMOTE CONTROLLER MANUAL 6 720 866 393 2019 11 GB Thank you very much for purchasing our air conditioner Please read this owner s manual carefully before using your air conditioner ...

Page 2: ...ller 13 NOTE Button design is based on typical model and might be slightly different from the actual one you purchased the actual shape shall prevail All the functions described are fulfilled by the unit If the unit does not have this feature there is no corresponding operation happening when pressing the relative button on the remote controller When there are wide differences between Remote contr...

Page 3: ...e Controller Specifications Climate 5000 6 720 866 393 2019 11 3 1 Remote Controller Specifications Model ARC R 1 IR Rated Voltage 3 0V AAA batteries Signal Receiving Range 8m Operating temperature 5ºC 60ºC ...

Page 4: ...hange the fan speed in AUTO or DRY mode 4 SLEEP Button Active Disable sleep function It can maintain the most comfortable temperature and save energy This function is available on COOL HEAT or AUTO mode only For the detail see sleep operation in USER S MANUAL NOTE While the unit is running under SLEEP mode it would be cancelled if MODE FAN SPEED or ON OFF button is pressed 5 TURBO Button Active Di...

Page 5: ... hold a button for more than 2 seconds the system will automatically restore the current operation settings including operating mode setting temperature fan speed level and sleep feature if activated 8 TIMER ON Button Press this button to initiate the auto on time sequence Each press will increase the auto timed setting in 30 minutes increments When the setting time displays 10 0 each press will i...

Page 6: ...then the temperature setting reverts back If the vertical louvre swing feature is stopped it displays LC and remains on for 3 seconds NOTE For some units the indoor units display when the swing feature is activated and display when the swing feature is stopped 11 Swing Button Used to stop or start horizontal louvre movement or set the desired up down air flow direction The louvre changes 6 degrees...

Page 7: ...Displayed when TIMER ON time is set Displayed when TIMER OFF time is set Show set temperature or room temperature or time under TIMER setting Displayed in Sleep Mode operation Not available for this unit Not available for this unit Not available for this unit Fan speed indication Low speed Medium speed High speed Auto fan speed Note All indicators shown in the figure are for the purpose of clear p...

Page 8: ...ng temperature on the remote controller 2 In the Auto mode you can not switch the fan speed It is automatically controlled 3 If the Auto mode is not comfortable for you the desired mode can be selected manually Cooling Heating Fan operation Ensure the power supply is on and all interconnecting wires are connected 1 Press the MODE button to select COOL HEAT cooling heating models only or FAN mode 2...

Page 9: ...ally controlled Adjusting air flow direction Use the SWING button to adjust the desired airflow direction 1 Up Down direction can be adjusted with the button on the remote controller Each time when you press the button the louvre moves an angle of 6 degree If pressing more than 2 seconds the louver will swing up and down automatically 2 Left Right direction can be adjusted with the button on the r...

Page 10: ... the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal H will disappear and the set temperature will re appear on the LCD display window To set the Auto off time 1 Press the TIMER OFF button The remote controller shows TIMER OFF the last Auto off setting time and the signal H will be shown on the LCD display area Now it is ready to ...

Page 11: ... 9 5 10 11 12 13 14 15 16 17 18 19 20 21 22 23 and 24 Example of timer setting TIMER ON Auto on Operation The TIMER ON feature is useful when you want the unit to turn on automatically before you return home The air conditioner will automatically start operating at the set time Example To start the air conditioner in 6 hours 1 Press the TIMER ON button the last setting of starting operation time a...

Page 12: ...nction is activated COMBINED TIMER Setting both ON and OFF timers simultaneously TIMER OFF TIMER ON On Stop Start operation This feature is useful when you want to stop the air conditioner after you go to bed and start it again in the morning when you wake up or when you return home Example To stop the air conditioner 2 hours after setting and start it again 10 hours after setting 1 Press the TIME...

Page 13: ...setting and stop it 5 hours after setting 1 Press the TIMER ON button 2 Press the TIMER ON button again to display 2 0H on the TIMER ON display 3 Press the TIMER OFF button 4 Press the TIMER OFF button again to display 5 0H on the TIMER OFF display 5 Wait for 3 seconds and the digital display area will show the temperature again The TIMER ON TIMER OFF indicator remains on and this function is acti...

Page 14: ...t or heat If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly If other electrical appliances react to the remote controller either move these appliances or consult your local dealer Do not drop the remote controller Handle with care Do not place heavy objects on the remote controller or step on it Using the remote controlle...

Page 15: ...cted by a cover 1 Remove the cover in the rear part of the remote controller 2 Remove the old batteries and insert the new batteries placing the and ends correctly 3 Install the cover back on NOTE When the batteries are removed the remote controller erases all programming After inserting new batteries the remote controller must be reprogrammed CAUTIONS Do not mix old and new batteries or batteries...

Page 16: ...Bosch Thermotechnology Ltd Cotswold Way Warndon Worcester WR4 9SW mailto Commercial enquiry uk bosch com Contact Number 03301233004 Web address www bosch industrial co uk ...