AUTODOME IP 4000i/AUTODOME IP 5000i/
AUTODOME IP 5000i IR
Alarm | en
47
Bosch Security Systems
User Manual
2018.05 | 1.1 |
8
Alarm
8.1
Alarm Connections
You can select how the camera responds to an alarm. In the event of an alarm, the unit can
automatically connect to a pre-defined IP address. You can enter up to ten IP addresses to
which the camera will connect in sequence in the event of an alarm, until a connection is
made.
Connect on alarm
Select
On
so that the camera automatically connects to a predefined IP address in the event
of an alarm.
By setting
Follows input 1
*, the unit maintains the connection that has been automatically
established for as long as an alarm exists on alarm input 1.
Notice!
In the default setting, Stream 2 is transmitted for alarm connections. Consider this when
assigning the profile (see Encoder Profile).
Number of destination IP address
Specify the numbers of the IP addresses to be contacted in the event of an alarm. The unit
contacts the remote stations one after the other in the numbered sequence until a connection
is made.
Destination IP address
For each number, enter the corresponding IP address for the desired remote station.
Destination password
If the remote station is password protected, enter the password here.
Only ten passwords can be defined here. Define a general password if more than ten
connections are required. The unit connects to all remote stations protected by the same
general password. To define a general password:
1.
Select 10 in the
Number of destination IP address
list box.
2.
Enter 0.0.0.0 in the
Destination IP address
field.
3.
Enter the password in the
Destination password
field.
4.
Set the user password of all the remote stations to be accessed using this password.
Setting destination 10 to the IP-address 0.0.0.0 overrides its function as the tenth address to
try.
Video transmission
If the unit is operated behind a firewall, select
TCP
(HTTP port)
as the transfer protocol. For
use in a local network, select
UDP
.
!
Caution!
Please note that in some circumstances, a larger bandwidth must be available on the network
for additional video images in the event of an alarm, in case Multicast operation is not
possible. To enable Multicast operation, select the
UDP
option for the
Video transmission
parameter here and on Network Access.
Stream