46
en | Installing the Roof Parapet and Pipe Mounts
AUTODOME IP starlight 7000i
2021-03 | 1.2 |
Installation Manual
Bosch Security Systems
i
Notice!
After all wiring is complete, close the cover door and tighten the two (2) captive screws on
the cover door to 10-12 N-m (90-105 in.-lbs) to ensure the Power Supply Box is watertight.
10.4
Installing the VG4-A-9543 Pipe Mount
This section details the installation steps for the VG4-A-9543 Pipe Mount. If you are installing
the Roof Parapet mount, refer to Installing the VG4-ROOF-MOUNT for instructions.
i
Notice!
Customer must supply 1-1/2 inch (NPS) pipe threaded on both ends with a minimum length
of 5 inches (12.7 cm).
You must use Teflon tape for thread-sealing compound.
All screws shall be tightened securely.
5 in.
12.7 cm
min.
Figure 10.5:
Pipe Mount
1
Gasket
2
Flange
3
Cap
1.
Before installing the Top-Mounting Flange, ensure there is an adequate opening in the
ceiling or mounting structure for the wires to pass through.
2.
Secure the pipe Flange with supplied gasket to the ceiling or other supporting structure
using four (4) 10-mm (3/8-inch) diameter fasteners.
i
Notice!
Each fastener must have a minimum pullout strength of 275 kg (600 lbs). The mounting
material must be able to withstand this pull-out force. For example, 19-mm (3/4-inch)
minimum for plywood.
3.
Attach pipe (not supplied) to the Top-mounting Flange.
!
Warning!
You must thread the pipe onto the Top-mounting Flange until it is tight. Failure to do so can
result in damage, serious injury or death.
4.
Route the power, video, control, and alarm wires through the Top-Mounting Flange and
down the pipe.
5.
Wrap at least five layers of Teflon tape around the threads.