60
en | Connection
AUTODOME IP starlight 7000i
2021-03 | 1.2 |
Installation Manual
Bosch Security Systems
2
Alarm Inputs 3 to 7
4
Ground
2.
From
Configuration
, select
Interfaces
>
Alarm Inputs
, select the number of the
Alarm
input
and finally, select N.O. See the table below for contact and condition details.
AUTODOME Programmed N.O.
Circuit
Alarm Indication
Open
Normal
Closed
Alarm
Configuring a Normally Closed Non-supervised Alarm
1.
Connect the alarm to the appropriate input (3 through 7) and ground at the camera.
Figure 13.5:
N.C. Normally Closed Non-supervised Connections
1
Dry Contact
3
Dome Connector
2
Alarm Inputs 3 to 7
4
Ground
2.
From
Configuration
, select
Interfaces
>
Alarm Inputs
, select the number of the
Alarm
input
and finally, select N.C. See the table below for contact and condition details.
AUTODOME Programmed N.C.
Circuit
Alarm Indication
Open
Alarm
Closed
Normal
Alarm Outputs
The camera incorporates two (2) types of alarm outputs: one dry contact relay and three (3)
open collector outputs or transistor outputs.
Configuring a Dry Contact Relay
The dry contact relay acts like an on/off switch. It has a maximum voltage rating of 2 A @
30 DC.
1.
Connect the appropriate stripped wire to the camera’s COM connector.
2.
Connect the appropriate stripped wire to the N.O. or N.C. connector, depending on your
requirement.
Configuring an Open Collector Output
Outputs 1, 2, and 3 are open collector types. These outputs must be connected to a positive
voltage between 5 and 32 V to complete the circuit, with a maximum voltage rating of 32 VDC
@ 150 ma.
1.
Connect the appropriate stripped wire to the open connector (1, 2, or 3) of the
transistor.
2.
Connect the appropriate stripped wire to the ground (GND) connector.