Conettix Universal Dual Path Communicator
Maintenance and troubleshooting | en
85
Bosch Security Systems, Inc.
Installation and Operation Manual
2017.11 | 05 | F.01U.311.207
Heartbeat
LED
RX LED
Plug-in Status LED
Function
Flashing
Off
Flashing (two flashes)
Indicates a cellular IP
address error. Check
with your service
provider to make sure
the cellular module
was setup correctly.
Flashing
Off
Flashing (three flashes)
Indicates the SIM
Card is missing. Verify
the SIM card is
inserted into the
B442 or B443 cellular
communication
module. Refer to the
troubleshooting
section for more
information.
Flashing
Off
Flashing (four flashes)
Indicates a SIM Card
lockout. This requires
that the SIM PIN be
used to unlock the
SIM card.
Flashing
Off
Flashing (five flashes)
Indicates an invalid
SIM PIN. Verify the
correct SIM PIN was
entered.
Refer to the
troubleshooting
section for more
information.
Tab.
11.11:
POWER LED descriptions
POWER LED
Flash pattern
Function
On Steady
Indicates a good Input Power level.
Flashing
Indicates Input Power is low (brownout) or failure.