Conettix Universal Dual Path Communicator
Communication Configuration | en
61
Bosch Security Systems, Inc.
Installation and Operation Manual
2017.11 | 05 | F.01U.311.207
7.7.1
Ethernet IP Address / Host Name
Default
:
blank
Selections
:
–
IPv4 - 0.0.0.0 to 255.255.255.255
–
IPv6 - 0000:0000:0000:0000:0000:0000:0000:0000 to
FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF
Enter an IPv4 address, an IPv6 address, or host name.
The B465 uses this IP address to send reports to the central station receiver over Ethernet
technology.
Further information
IP Address and Domain Name formats
USB Menu Location
[2] Standard Communication Configuration > [4] Primary Receiver > [2] Ethernet IP Address /
Host Name
- or -
[3] Advanced Communication Configuration > [2] Receiver Setup > [1] Primary Receiver > [2]
Ethernet IP Address / Host Name
7.7.2
Port Number
Default
:
7700
Selections
: 1 to 65,535
This is the port number the B465 uses for communication with the central station receiver.
USB Menu Location
[2] Standard Communication Configuration > [4] Primary Receiver > [1] Port Number
- or -
[3] Advanced Communication Configuration > [2] Receiver Setup > [1] Primary Receiver > [1]
Port Number
7.7.3
Ethernet Supervision Time
Default
:
1 hour
Selections
:
–
No polling
–
90 seconds
–
180 seconds
–
200 seconds
–
5 minutes
–
1 hour
–
4 hours
–
24 hours
The B465 must receive an ACK (acknowledgement) to a heartbeat poll within the time defined
by the Ethernet Supervision Time parameter. To reduce network traffic, the B465 adjusts the
heartbeat poll rate, ACK wait time, and Retry Count to support the Ethernet Supervision Time
you select.
If the B465 does not receive an ACK to a heartbeat poll after the retry count is met, it creates
a Communication Trouble event.
USB Menu Location
[2] Standard Communication Configuration > [4] Primary Receiver > [3] Ethernet Supervision
Time
- or -