62
en | Communication Configuration
Conettix Universal Dual Path Communicator
2017.11 | 05 | F.01U.311.207
Installation and Operation Manual
Bosch Security Systems, Inc.
[3] Advanced Communication Configuration > [2] Receiver Setup > [1] Primary Receiver > [3]
Ethernet Supervision Time
7.7.4
Cellular IP Address / Host Name
Default
:
blank
Selections
:
–
IPv4 - 0.0.0.0 to 255.255.255.255
–
IPv6 - 0000:0000:0000:0000:0000:0000:0000:0000 to
FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF
Enter an IPv4 address, an IPv6 address or host name.
The B465 uses this IP address to send reports to the central station receiver over Cellular
technology.
Further information
IP Address and Domain Name formats
USB Menu Location
[2] Standard Communication Configuration > [4] Primary Receiver > [4] Cellular IP Address /
Host Name
- or -
[3] Advanced Communication Configuration > [2] Receiver Setup > [1] Primary Receiver > [4]
Cellular IP Address / Host Name
7.7.5
Cellular Supervision Time
Default
:
1 hour
Selections
:
–
No polling
–
90 seconds
–
180 seconds
–
200 seconds
–
5 minutes
–
1 hour
–
4 hours
–
24 hours
The B465 must receive an ACK (acknowledgement) to a heartbeat poll within the time defined
by the Cellular Supervision Time parameter. To reduce network traffic, the B465 adjusts the
heartbeat poll rate, ACK wait time, and Retry Count to support the Cellular Supervision Time
you select.
If the B465 does not receive an ACK to a heartbeat poll after the retry count is met, it creates
a Communication Trouble event.
USB Menu Location
[2] Standard Communication Configuration > [4] Primary Receiver > [5] Cellular Supervision
Time
- or -
[3] Advanced Communication Configuration > [2] Receiver Setup > [1] Primary Receiver > [5]
Cellular Supervision Time
7.7.6
AES Encryption, Key Size
Default
:
No Encryption (Disabled)
Selections
:
–
No Encryption (Disabled)
–
128 bits - 16 bytes
Summary of Contents for B465