Conettix Universal Dual Path Communicator
Communication Configuration | en
65
Bosch Security Systems, Inc.
Installation and Operation Manual
2017.11 | 05 | F.01U.311.207
–
200 seconds
–
5 minutes
–
1 hour
–
4 hours
–
24 hours
The B465 must receive an ACK (acknowledgement) to a heartbeat poll within the time defined
by the Cellular Supervision Time parameter. To reduce network traffic, the B465 adjusts the
heartbeat poll rate, ACK wait time, and Retry Count to support the Cellular Supervision Time
you select.
If the B465 does not receive an ACK to a heartbeat poll after the retry count is met, it creates
a Communication Trouble event.
USB Menu Location
[3] Advanced Communication Configuration > [2] Receiver Setup > [2] Secondary Receiver >
[5] Cellular Supervision Time
7.9.6
AES Encryption, Key Size
Default
:
No Encryption (Disabled)
Selections
:
–
No Encryption (Disabled)
–
128 bits - 16 bytes
–
192-bit - 24 bytes
–
256-bit - 32 bytes
Select the key size for AES encryption.
USB Menu Location
[3] Advanced Communication Configuration > [2] Receiver Setup > [2] Secondary Receiver >
[6] AES Encryption
7.9.7
AES Encryption Key
Default
: <Default> (not encrypted)
Selections
: Thirty-two hexadecimal characters represented by an ID (01 to 100).
The AES Encryption Key is based on AES Key Size.
AES key strings are configured
in Config > System > Encryption Key Tab
USB Menu Location
[3] Advanced Communication Configuration > [2] Receiver Setup > [21] Secondary Receiver >
[7] AES Encryption Key
7.10
Ethernet Setup
Use the parameters in this section to configure the B465 for IPv6 or IPv4 communication.
7.10.1
IPv6 Mode
Default
:
Disabled
Selections
:
–
Enabled - use IPv6 mode (Internet Protocol version 6) for IP communications.
–
Disabled - use IPv4 mode (Internet Protocol version 4) for IP communications.
USB Menu Location
[3] Advanced Communication Configuration > [3] Ethernet Setup > [1] IPv6 Configuration >
[1] IPv6 Mode
7.10.2
IPv6 DNS Server IP Address
Default
: blank
Summary of Contents for B465
Page 1: ...Conettix Universal Dual Path Communicator B465 en Installation and Operation Manual ...
Page 2: ......