16
17
Advanced Settings
Advanced Settings allow HVAC professionals
the ability to modify specific thermostat
settings for better control of the heating and
cooling appliance(s). In order to access the
Advanced Settings of the BCC50
Thermostat, your thermostat must be
connected to Wi-Fi. The Advanced Settings
section is accessible from the Menu of the
BCC50 smartphone app.
NOTE: Advanced Settings are for
professional use only and require
access code: 1886
Advanced Settings
Heating & Cooling
u
To access the Hveating and Cooling, click Heat – Cool on the Advanced Settings screen and enter the
Professional Access Code.
u
Click on a setting and use the scroll wheel to modify the default value. From this menu you can adjust:
TITLE Default
Max
Min
Description
Fan Delay On
The fan’s lag time after the heating or cooling call is initiated when in Fossil Fuel, Heat Pump, or
Cooling operation.
Fan Delay On Elec
The fan’s lag time after the heating or cooling call is initiated when in Electric, Auxiliary, or
Emergency operation.
Fan Delay Off
The fan’s lag time after the heating or cooling call is terminated.
Min. Run Time
The minimum amount of time the system will cycle upon engagement.
Anti Short Cycle
The Anti Short Cycle (ASC) timer represents the minimum amount of time the system will remain
off upon stage down engagement.
Cycle Time
Time delay between heating and cooling transition
Zero Energy
Band Heating
A temperature range between the current temperature and the heating set point, where heating is
not engaged (also called deadband).
Zero Energy
Band Cooling
A temperature range between the current temperature and the cooling set point, where cooling is
not engaged (also called deadband).