30 | BSA 7xxx / 8xxx | Technical Data
1 691 806 123
2017-06-23
|
Beissbarth GmbH
en
7.3
Electrical cabinet
7.3.1
Roller set
Basic data:
Designation
230 VAC
400 VAC
Dimensions (L x W x H)
380 x 600 x 850 mm
380 x 600 x 850 mm
Weight
28 kg
25 kg
Degree of protection (as per
DIN 40 050)
IP 20
IP 20
Power data 230 VAC:
Designation
BSA 7xxx
BSA 8xxx
Voltage supply
4 x 230 V
Power supply cable*
5 x 35 mm²
Fuse* (C, 3-pole)
3 x 100 A
Make-break capacity of main
switch
125 A
Power supply unit
R
Primary
R
Secondary
R
Power
90 - 264 V
24 V
48 VA
Power data 400 VAC:
Designation
BSA 7xxx
BSA 8xxx
Voltage supply
3 x 400 V
Power supply cable*
4 x 10 mm²
Fuse* (C, 3-pole)
3 x 50 A
Make-break capacity of main
switch
80 A
Power supply unit
R
Primary
R
Secondary
R
Power
90 - 264 V
24 V
48 VA
The specifications for the power supply cable and fuse (*) are only intended as a guide:
R
National standards and the applicable regulations must be observed with respect to the power supply cable
and fuse protection.
R
The power supply cable and fuse ratings must be matched to the tester installed. In the case of test lanes, they
must be appropriate to the most powerful tester.