Carephone 61
Product Description | en
11
Bosch Security Systems
User Manual
F.01U.239.30x | V1 | 2011.06
4.4.2
Sound signal in synthetic speech disabled mode
When the Carephone 61 is in synthetic speech disabled mode,
certain technical messages are announced by sound signals.
4.4.3
Local voice announcements from the unit
When pressing a button
Error messages
Sound Signal
Meaning
1 beep
power failure
2 beeps
line failure
3 beeps
battery empty
4 beeps
transmission failure
Voice announcement
Meaning
"Emergency call"
When the emergency call button is pressed.
"Call activated"
Connection failed - unit is calling again.
"Stop"
When the action button is pressed during the pre-
alarm. The call is cancelled.
"Service call"
When the action button is pressed, if it is
programmed as a service button or direct call.
"Emergency call cleared" When a repeated call is acknowledged on the unit.
"Call ended"
When a call back is acknowledged on the unit.
"Radio button[x]"
When a wireless transmitter is pressed, x being
the number of the transmitter, from 1 to 10.
"Alarm input"
When the external alarm input is activated.
Voice announcement
Meaning and Action needed
"Power failure"
Power failure. Check the power connection.
"Line failure"
Connection to the telephone network has been
lost. Check the connection.
"Transmission failure"
Emergency call not sent. Contact monitoring
centre.
"Unit battery empty"
Backup battery is empty. Connect to the mains
power supply. Contact the monitoring centre.