Extension cables
Adding an extension cable longer than 20 m (66.0 ft) to a trunk/tap-off has a direct effect on
the available power for the components connected in the daisy chain. A component can be a
Discussion Device or an Extension Unit.
Use the following table to determine the total number of components that can be connected
to a trunk/tap-off when one or more extension cables are connected to that trunk/tap-off.
–
Limit 1: The maximum cable length for a trunk/tap-off is 100 m (328.0 ft). This includes
all extension cables (including the first 20 m (66.0 ft) of extension cable) + the Discussion
Device cables of 2 m (6.6 ft) per device. + the Extension Unit cables.
Total length of extension cable(s) per trunk/
tap-off
Maximum number of components per trunk/
tap-off
0 m to 20 m
40
20 m to 22 m
39
22 m to 24 m
38
24 m to 26 m
37
26 m to 28 m
36
28 m to 30 m
35
30 m to 32 m
34
32 m to 34 m
33
34 m to 36 m
32
36 m to 38 m
31
38 m to 40 m
30
40 m to 42 m
29
42 m to 44 m
28
44 m to 46 m
27
46 m to 48 m
26
48 m to 50 m
25
50 m to 52 m
24
52 m to 54 m
23
54 m to 56 m
22
56 m to 58 m
21
58 m to 60 m
20
60 m to 62 m
19
62 m to 64 m
18
64 m to 66 m
17
66 m to 68 m
16
4.5.3
20
en | Planning
Digital Discussion System
2016.05 | V2.0 |