Problem
Possible cause
Possible solution
USB memory stick damaged.
–
Check the read/write
possibilities of the USB
stick.
–
Note: If the Control Unit
does not detect the USB
memory stick, it will
automatically record files
to the internal memory
instead.
–
Replace the (faulty) USB
memory stick.
Poor web browser
performance.
Multiple users are logged into
the same web browser.
Make sure only one user is
logged into a web browser. If
multiple users need to log in
at the same time:
–
use a different browser
type for each user, or
–
log in using a separate
device (tablet, laptop or
PC).
The tablet, laptop or PC loses
the connection with the
control unit.
–
Activating or deactivating
the fixed IP address in
the web browser
interface.
–
Changing the hostname.
Close and then reopen the
web browser interface.
Part of system not working
correctly.
Interrupted system cabling.
–
Check all trunk
connections between the
Discussion Devices and
the Control Unit.
–
Check the connections
of the auxiliary
equipment.
The external SDI video
switcher does not switch
between inputs.
Switcher has incorrect
settings.
Reset the switcher to factory
defaults. Then set the TCP
connection port number.
–
For the Kramer MV‑6
switcher, set the TCP
connection port number
to 5000.
–
For the
tvOne CORIOmatrix
switcher, set the TCP
connection port number
to 10001.
60
en | Troubleshooting
Digital Discussion System
2016.05 | V2.0 |
Operation manual
Bosch Security Systems B.V.