Robert Bosch Engineering and Business Solutions Private  Limited 

 

 

 

 

Be sure that the service technician uses replacement 
parts  specified  by  the  manufacturer,  or  that  which 
have  the  same  characteristics  as  the  original  parts. 
Unauthorized  substitutions  may  cause  injuries  or 
other hazards. 

The IMPORTANT SAFEGUARDS and WARNINGS 

presented  in  this  manual  do  not  cover  all  possible 
conditions that may occur. Common  sense, caution 
and  care  must  be  exercised  when  installing, 
maintaining or operating the unit. 

 

1.5

 

Important Notices 

 

Accessories 

- Do not place this unit on an 

unstable stand, tripod, bracket, or mount. 
The unit may fall, causing serious injury 
and/or  serious  damage  to the  unit. Use 
only  with  mounting  solutions  specified 
by the manufacturer. When a cart is used, 
use  caution  and  care  when  moving  the 
cart/unit combination to avoid injury from 
tip-over. Quick stops, excessive force, or 
uneven surfaces may cause the cart/unit 
combination to overturn. Mount the unit as 
per the installation instructions. . 

 

 

1.5.1

 

Don'ts 

 

Do not connect the unit to the electrical power supply 
using cables that have been damaged. 

 

Do not remove any of the connectors. 

 

Do not keep the unit below water body and water 
pipes. 

 

Do not keep the unit in temperature range other than 
indicated in recommendation section. 

 

Do not power the unit with other power sources than 
the  original  provided  by  RBEI.  Voltage  and  current 
maximum ratings can be exceeded, stopping unit from 
working and voiding warranty. 

 

Do not try to extract, screw, break or move connectors 
far from necessary usage, waterproof sealing can be 
damaged and warranty will be voided. 

 

Do not connect any sensor not provided by RBEI. 

 

Do not place nodes on places or equipment where 
it could be exposed to shocks and/or big vibrations. 

 

Do not keep mating connectors or dust caps in unlock 
condition. 

 

Do not use dropped unit. 

 

Do not replace the sensor or any parts in the mounting 
condition. 

 

Do not carry the unit in assembled condition (with sun 
shade, splash guard, hose clamp and screw hardware). 

 

Do not mishandle CO

and UV sensor as it may cause 

reading disturbance due to vibration or shock. 

1.5.2

 

Environmental statement 

Bosch has a strong commitmenttowards the environment. 
This unit has been designed to respect the environment 
as much as possible. 

 

1.5.3

 

Moving 

Disconnect the power before moving the unit. Move the 
unit with care. Excessive force or shock may damage the 
unit. 

 

1.5.4

 

Unpacking 

 

This  equipment  should  be  unpacked  and  handled 
with care. If an item appears to have been damaged in 
shipment, repack it in the original packaging and notify 
the shipping agent or supplier immediately. 

 

Verify that all the parts listed in the parts list below 
are included. If any items are missing, notify your RBEI 
representative. 

 

The original packing carton is the safest container to 
transport the unit and must be used if returning the 
unit for service. Save it if possible, for future use. 

 

1.5.5

 

3/CP300H (3.6V NI-MH BATTERY) & CR2032H 
BATTERY: 

Caution: 

Risk of explosion if battery is replaced by an 

incorrect  type. 
Dispose of used batteries (3/CP300H & CR2032H 
battery) according to the  instructions. 

Refer section 8.1 

en 

4 | Symbols and safety precautions 

Summary of Contents for CLIMO A D00 A40 103

Page 1: ...MicroClimateMonitoringSystem BOSCH CLIMO ...

Page 2: ... CLIMO overview 6 2 1 Version of product 6 11 FCC Warningstatement 15 105 17 2 2 Applications 6 2 3 Site Parameter selection as per CPCB guidelines on measurement of Ambient Air 12 Statement 17 Pollutants Air Quality 6 2 4 Device specifications 7 13 Mobile Device 17 2 5 Technical data 8 14 RED Requirement 17 3 Pre Installation 9 3 1 Installation Kit 9 3 2 Tools 9 3 3 Torque table 9 3 4 SIM inserti...

Page 3: ...00mm all round the unit Do not place objects filled with liquids such as vases or cups on the unit Never spill liquid of any kind on the unit Donotopenthe mating connectorand dustcap inrainy 1 2 Symbols in this documentation Symbol Designation Explanation Attention Warns about possible property damage i Information Practical hints and other useful information 1 2 Multi step operation Instruction c...

Page 4: ...ranty Do not try to extract screw break or move connectors far from necessary usage waterproof sealing can be damaged and warranty will be voided Do not connect any sensor not provided by RBEI Do not place nodes on places or equipment where it could be exposed to shocks and or big vibrations Do not keep mating connectors or dust caps in unlock condition Do not use dropped unit Do notreplace the se...

Page 5: ...e covers are to be placed at 180 with bottom support Don ts Do not rest enclosure cover on vent kits Do not rest enclosure itself on vent kit 1 7 Short information Alleffortshave beenmade toensuretheaccuracyofmaterialprovidedin thisdocumentatthe time ofrelease However the items described in this document are subject to continuous development and improvement All specifications are subjected to chan...

Page 6: ...variation in sensor behavior due to limitation of NO NO2 and O3 sensors on higher temperature range beyond 40 C and PM sensor for below 10 C 2 2 Applications Real Estate and Community BOSCH CLIMO will be the indicator for quality of life index and the breathability of the ambient air The recommendations and early warning system based on air profiling will help the society to make smarter choices S...

Page 7: ...ing and Business Solutions Private Limited 2 4 Device specifications This section shows the overall dimensions of the BOSCH CLIMO design Detailed installation steps are explained in further sections Fig 1 Mounting envelope BOSCH CLIMO overview 7 en ...

Page 8: ...s and shock protection Power supply 100VAC 240VAC 50 60 Hz or 9 12 V DC Maximum power rating 20W Ambient Operating Temperature 20 C 50 C Humidity 15 85 RH Enclosure UV stabilized industrial housing molded fiberglass reinforced polyester Color RAL 7035 light gray System weight 6 kgs Dimension L x W x H L 30cm x W 25cm x H 15cm Compact housing Certifications 3G Ethernet version CE and FCC certified ...

Page 9: ...ectors i Refer to the Connector website for installation of Ethernet cable with Ethernet mounting connector i MatingconnectorisnotpartofBOSCHCLIMOunit It is recommended to use IP65 compliant mating connectorsmentionedinthetablebelow Mating connector Mfr Part Number Description Ethernet Conec 17 10001 Plug modular connector 8p8c RJ45 Ethernet position shielded Cat5e IDC USB Conec 17 200121 USB A US...

Page 10: ...cles 3 8 Health indicators You can know the device is functional by checking the red LED indicator Blinking of this LED indicates that there is a proper connection of the BOSCH CLIMO device with cloud and the data is being transmitted successfully 3 9 Pre installation Acceptance checklist iTake the print out of the checklists sign and store it for every unit Sl No Description Test Passed Yes No NA...

Page 11: ...lash guard CO2 Sensor assembly UV sensor assembly Solar Shade 2 Ensure mating connectors and dust caps should be in locked condition 3 Connection details Ethernet 3G 4 Switch on the unit and observe blinking of the red LED 5 Ensure the device updating the data on the cloud verified by customer using their system 6 Picture of installation in four direction 7 Details of the four direction at the loc...

Page 12: ...tallation kit 4 Check the delivery carefully to make sure that all parts have been delivered If there is any mistake please contact your authorized dealer atonce Fig 2 Packaging i Intheinstallationkit partsforbothwallmountingand pole mounting are available i Keep the original package for the future transporting 4 2 Installing SIM To install SIM in the unit Ensure to take necessary ESD precautions ...

Page 13: ...ed as space is required to fix the screw through the mounting bracket 1 Fix the UV sensor on the sun shade from bottom first 4 5 Wall mounting To wall mount the unit 1 Use the wall mounting template to mark out the four mounting holeson the wall 2 Drill holes on the marked points of the wall i The mounting holes should be such that it can accommodate the proposed wall plugs and screws 3 Insert the...

Page 14: ...not a load carrying componentand can cause damage Do not rest the unit on splash guard i While assembling handle CO2 sensorwithcareand avoid installing any other equipment around the sensor Fig 8 Splash guard with CO2 sensor 4 8 ACDCconnection To connect AC or DC cable to the unit 1 When the unit is assembled either on pole orwall check that the unit is in perfect condition and without anydamage 2...

Page 15: ...he range and associated health risks for each category are as follows AQI category Range Associated health impacts Good 0 50 Minimal impact Satisfactory 51 100 May cause minor breathing discomfort to sensitive people Moderately polluted 101 200 May cause breathing discomfort to people with lung disease such as asthma and discomfort to people with heart disease children and older adults Poor 201 30...

Page 16: ... faced to south north if you are on the south hemisphere and tilted 45º Always place the unit such that the connectors and antenna face towards either to west or east Keep the unit out of range of people who can damage installation wet sensors etc As per sensor manufacturer s specification sensors are capable of producing accurate data under stable temperature humidity The standard test conditions...

Page 17: ...mmunications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase t...

Page 18: ...Robert Bosch Engineering and Business Solutions Private Limited 123 Industrial Layout Hosur Road Koramangala Bangalore 560 095 INDIA ...

Reviews: