Table 98:
Modem4/ModemIIIa² Messages
Event
Device/Mode Display/Explanation
Comments
543
Service End
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SERVICE END
+++ACC aaaa
AREA=a
h1rrlssssssaaaasRsssFt
<header>[#aaaa|NriaTE]
544
Service End
(No Area)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SERVICE END
+++ACC aaaa
ID=iii
h1rrlssssssaaaasRsssFt
<header>[#aaaa|NidiiiTE]
545
Service Request
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SERVICE REQUEST
h1rrlssssssaaaasNsD45t
<header>[#aaaa|NYX]
546
Service Start
(2212)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SERVICE START
h1rrlssssssaaaasTsssFt
<header>[#aaaa|NTS]
547
Service Start by User
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SERVICE START
+++ACC aaaa
AREA=a ID=iii
h1rrlssssssaaaasTsssFt
<header>[#aaaa|Nria/idiiiTS]
548
Service Start
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SERVICE START
+++ACC aaaa
AREA=a
h1rrlssssssaaaasTsssFt
<header>[#aaaa|NriaTS]
549
Service Start
(No Area)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SERVICE START
+++ACC aaaa
ID=iii
h1rrlssssssaaaasTsssFt
<header>[#aaaa|NidiiiTS]
550
Service Start by User
(4-digit User)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SERVICE START
+++ACC aaaa
AREA=aa ID=iiii
h1rrlssssssaaaasTsssFt
<header>[#aaaa|Nriaa/idiiiiTS]
551
SKED Bypass
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SKED BYPASS
+++ACC aaaa
AREA=a POINT=ppp SKED=kkk
h1rrlssssssaaaasNspppt
<header>[#aaaa|Nria/aikkkUBppp]
552
SKED Bypass
(4-digit Point)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SKED BYPASS
+++ACC aaaa
AREA=aa POINT=pppp SKED=kkk
h1rrlssssssaaaasNppppt
<header>[#aaaa|Nriaa/aikkkUBpppp]
553
SKED Changed
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SKED CHANGED
+++ACC aaaa
SKED=kkk
h1rrlssssssaaaasNsD06t
<header>[#aaaa|NaikkkJS]
554
SKED Changed by User
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SKED CHANGED
+++ACC aaaa
ID=iii SKED=kkk
h1rrlssssssaaaasNsD06t
<header>[#aaaa|Nidiii/aikkkJS]
555
SKED Changed by User
(4-digit User)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SKED CHANGED
+++ACC aaaa
ID=iiii SKED=kkk
h1rrlssssssaaaasNsD06t
<header>[#aaaa|Nidiiii/aikkkJS]
556
SKED Executed
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
SKED EXECUTED
+++ACC aaaa
SKED=kkk
h1rrlssssssaaaasNsD25t
<header>[#aaaa|NaikkkJR]
557
Status: Alarm
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
S:ALARM
+++ACC aaaa
AREA=a POINT=ppp
h1rrlssssssaaaaSAspppt
<header>[#aaaa|OriaBAppp]
558
Status: Alarm
(4-digit Point)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
S:ALARM
+++ACC aaaa
AREA=aa POINT=pppp
h1rrlssssssaaaaSAppppt
<header>[#aaaa|OriaaBApppp]
559
Status: Analog Service
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
S:ANALOG SERVCE
+++ACC aaaa
AREA=a POINT=ppp
h1rrlssssssaaaaSTspppt
<header>[#aaaa|OriaASppp]
560
Status: Analog Service
(Level & Value)
Printer:
D6500 Mode:
SIA Mode:
dd/dd tt:tt Lxx ACC aaaa
S:ANALOG SERVCE
+++ACC aaaa
AREA=a POINT=ppp
+++ACC aaaa
LEVEL=lll VALUE=vvv
h1rrlssssssaaaaSTspppt
<header>[#aaaa|Oria/lvlll/vavvvASppp]