3.2.8
Caller ID (Message Type <TAB>)
SIA Example
SIA Mode Description
<LF><CRC><TAB><sequence#><receiver#><line#>[#0000|&TTTTTTTTTTTTTTTT]<CR>
Table 54: Caller ID (Message Type <TAB>) Byte Description
Title
Description
LF
Standard line feed character.
CRC
Cyclical Redundancy Check number.
Message Type
<TAB>
sequence#
The message sequence number. The valid sequence number range is
0001 to 9999.
receiver#
The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6..
line#
(Line/Group #)
The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.
&
Origin ID Block.
T
Up to 16-digit Caller ID.
Figure 13: Message sent to Printer
30/04 17:00 L01 CLI 9563832510