Conettix Datagram Type Differences
i
Notice!
Install software version 5.5C or later in the network device (C900TTL-E, D9133TTL-E, or
D6680) for the Datagram Type Function.
Software version 1.5D or later must be installed in the DX4020 or C900V2.
i
Notice!
If you are using a D6686 or D6100IPv6, the datagram section does not apply to the receiver
configuration.
Datagram 02
This datagram uses the IP address and the port number to identify and ACK packets from the
receiver to the field devices which allow multiple devices to be installed behind a single
outgoing IP address. This datagram type requires that CPU version 01.02.01 or later is
installed, and that receiver parameter 6.8.6 is programmed as 1.
To use this datagram type, program it in the following order:
1.
Confirm that D6200 version 1.20 or later is installed.
2.
Confirm that the D6600 CPU version 01.02.01 is loaded in the receiver.
3.
With the D6200 software, select Network
→
Network Configuration Management
→
Read/Manage Network Configuration from Receiver.
4.
Select the 6.8 Global Parameters tab.
5.
Change the 6.8.6 6600 Datagram Type value to 1.
6.
Send the changes to the receiver and close the window.
7.
Select Network
→
Network Utilities
→
Network Device Setup and select the Telnet to
Device tab.
8.
Type or find the IP address of the D6680/D6682 in the list and establish a telnet session
with the D6680/D6682.
9.
After establishing the telnet session, select the channel(s) to use by pressing [1] or [2],
and then press Enter.
10. Press Enter until you have selected Datagram and type 02, then press Enter, If both
channels are used, change both channels.
11. Save the settings and exit from the D6680/D6682 setup.
Datagram 07
i
Notice!
This datagram is supported only on the E2‑RAD version of the D9133TTL-E Network Interface
Module.
This datagram type is used only in the NIM of the network device (D9133TTL-E, or DX4020).
The datagram type allows the Source and Destination ports to be set independently. This use
of a different source port allows NAT (Network Address Translation) tables of routers or
firewalls to direct packets to the correct NIM of the field device.
To use this datagram type, program in the following order:
1.
Telnet to the NIM of the field device as described in the appropriate network device
(D9133TTL-E or DX4020) installation guide.
2.
Select channel 1 of the NIM.
12.2.3
Conettix Communications Receiver/
Gateway
Network Communications | en
53
Bosch Security Systems, Inc.
Installation and Operation Guide
2012.11 | 08 | 4998122704