Bosch Security Systems, Inc. | 11/12 | F01U274797-02 

 

3.0

 

Configuring and 
Programming the D6686 

3.1

 

Factory Default IP Address 

By default, the D6686 uses DHCP to obtain an IP 
Address. The unit requires a static IP Address. 
Refer to 

Sections

 

3.2

3.3

, and 

3.4

 for more 

information. 

3.2

 

Identifying the MAC Hardware 

Address 

1.

 

Verify that the D6686 is properly installed, 
connected, and powered. 
Refer to 

Section 2.0 Installation

 on page 4. 

2.

 

Locate the D6686’s media access control 
(MAC), or hardware, address. 

The MAC address is hard-coded into the 
D6686 during manufacturing, and it cannot 
be changed. This address is 6 bytes (12 
digits) in length and is located on a label on 
the D6686 in the format of “xx-xx-xx-xx-xx-xx”. 

 

Figure 4: MAC Address Location 

 

1-

 

MAC address location on D6686 label 

 

3.

 

Record the MAC address and keep it for 
reference. 

3.3

 

Obtaining an IP Address 

Provide the D6686’s MAC address to the site’s 
network administrator, who will assign an IP 

address for the D6686. 
An IP Address is an identifier for a computer or 
device on a transmission control 
protocol/internet protocol (TCP/IP) network. 
Networks use the TCP/IP protocol route 
messages based on the IP address of the 
destination. The format of an IP address using 
IPv4 is a 32-bit numeric address written as four 
numbers or fields separated by periods. Each 
number can be 0 to 255. The format of an IP 
address using IPv6 is a 128-bit numeric address 
written as eight groups of four hexadecimal digits 

separated by colons. 

For example, 190.200.128.111 could be an IPv4 
address and 
2001:0db8:85a3:0042:0000:8a2e:0370:7334 
could be an IPv6 address. Within an isolated 
network, you can assign IP addresses at random 
if each one is unique. However, connecting a 
private network to the Internet requires using 
registered IP addresses (called Internet 
addresses) to avoid duplicates. IPv6 addresses 
are typically set using DHCP on the network. The 
D6686 supports IPv4 and/or IPv6 addressing 

schemes or both at the same time. 
 

3.4

 

Using the D6200 to configure the 

D6686 

Bosch Security Systems, Inc. recommends that 
you read this entire section before proceeding. 

 

 

In order to access the configuration 
program, ensure that the D6686 
and the PC used to configure it are 
directly connected using an 
Ethernet cable. 
Be sure that the PC being used to 
configure the device is configured 
to use DHCP to obtain an IP 
Address. When it is connected 
directly to the D6686 it will obtain 
an Auto-IP address. 

 

The D6200 Software is the recommended way to 
program the network devices. Review 

Section

 

3.5 

Programming Overview for the D6600

 on page 8 

and the 

Network Utilities section

 in the 

D6200 

Programming Software Operation and Installation 
Guide

 (P/N: 4998154991). 

1.

 

When you have the IP address and the 
network administrator confirms that it is 
ready, connect the Ethernet port of the 
D6686 directly to the PC Ethernet port 
using an Ethernet cable. 

2.

 

With the PC already booted and running, 
apply power to the D6686 and wait 
approximately 1 minute for the PC and 
D6686 to acquire an Auto-IP Address 
(169.254.xxx.xxx). 

 

 

1

Summary of Contents for Conettix ITS-D6686-INTL

Page 1: ...EN Installation Guide Ethernet Network Adapter Conettix ITS D6686 INTL ...

Page 2: ... Serial Interface 3 1 3 LEDs 3 2 0 Installation 4 2 1 Mounting the D6686 4 2 2 Connecting the D6686 4 3 0 Configuring and Programming the D6686 5 3 1 Factory Default IP Address 5 3 2 Identifying the MAC Hardware Address 5 3 3 Obtaining an IP Address 5 3 4 Using the D6200 to configure the D6686 5 3 5 Programming Overview for the D6600 8 4 0 Specifications 9 ...

Page 3: ...J45 Ethernet Jack 3 Ethernet Activity LED 4 Reset Pin 5 Power Plug 1 2 Serial Interface Figure 2 D6686 Network Interface 1 Power Diagnostic LEDs 2 Serial Port 2 DTE optional use supplied cable if required 3 Serial Port 1 DTE use supplied null cable 1 3 LEDs Table 1 D6686 LEDs LED Description Power Diagnostic Blue Steady On Power OK Blinking 2x No DHCP response Blinking 2x Setup Menu active RX Seri...

Page 4: ...necting the D6686 Connect the D6686 as follows Power cable to an available electrical outlet Ethernet cable to network switch RS 232 serial cable to Serial 1 port Refer to the D6600 D6100IPv6 Installation and Operation Guide Network Communication section P N 4998122704 for applications using both serial ports Refer to Figure 3 Figure 3 D6686 Connections 1 Power cable 2 Ethernet cable 3 RS 232 seri...

Page 5: ...s a 128 bit numeric address written as eight groups of four hexadecimal digits separated by colons For example 190 200 128 111 could be an IPv4 address and 2001 0db8 85a3 0042 0000 8a2e 0370 7334 could be an IPv6 address Within an isolated network you can assign IP addresses at random if each one is unique However connecting a private network to the Internet requires using registered IP addresses ...

Page 6: ...address that is listed is shown 6 Select XML Configuration tab and click the Setting button Enter in the Setting dialog D6686 D6100IPv6 IP The IP address recorded in the previous step FTP User Name admin FTP Password PASS Click OK 7 Click the Open XML button select D6686 xml and click Open 8 Make changes to the parameters that are required for your particular installation scenario by selecting the...

Page 7: ...Conettix ITS D6686 INTL Installation Guide 3 0 Configuring and Programming the D6686 Bosch Security Systems Inc 11 12 F01U274797 02 7 ...

Page 8: ...ork interface module DX4020 C900V2 C900TTL E or D9133TTL E must have the proper software version to support encryption For more details refer to the Device Installer Operation and Installation Guide P N 4998138688 3 5 Programming Overview for the D6600 The D6600 Receiver is shipped with factory default program parameters and features already installed Descriptions of the program items are found in...

Page 9: ...ne Formats Characters 7 or 8 data bits Stop bits 1 or 2 Parity Odd even none Modem Controls DTR DSR Flow Control Software XON XOFF Hardware CTS RTS Management FTP SNMP read only Serial login Telnet login System Software Flash ROM standard downloadable from a TCP IP host TFTP FTP or over serial port Diagnostic LEDs Power 10 100 Mb Link on RJ45 10 100 Activity on RJ45 RX Serial 1 Activity TX Serial ...

Page 10: ... 2012 Bosch Security Systems Inc F01U274797 02 Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 9199 800 289 0096 ...

Reviews: