background image

Graphic Keypads

Installer Reference Guide

3

Bosch Security Systems     03/16    Graphic Keypads BIRG FTR1.0

The Solution Graphic Keypad’s décor-friendly white plastic housing and stylish curved face blends with the most dis-
cerning of interior designs and can be used with or without the hinged door according to individual customer taste 
or requirements.  

All system programmable features and options are displayed in full text on the 
keypad allowing the system to be programmed and configured without refer-
ring to the manual. Different models are available including versions with built-
in Smart Card readers and Wi-Fi connectivity.

Keypads include red, green and blue indicators which are used to show area /
door status and the 20 buttons with blue backlighting make it easy to operate 
in all lighting conditions. Refer to the panel Installer Reference Guide for more 
information on keypad options and panel programming.

      

Solution 6000 Keypad Compatibility

Keypad Model

Panel Version

Keypads Supported

CP700B

All versions

Up to 16

CP710B

All versions

Up to 16

CP722B

All versions

Up to 16

CP732B

All versions

Up to 16

CP741B with Wi-Fi

2.25 or higher

1 Only (address 1)

Table 1: Keypad Compatibility

Keypad Addressing

Each keypad fitted to the system must be assigned a unique address on the LAN.  For convenience the address dip 
switch configuration table shown below is also provided on the rear of the plastic keypad housing.  
 
Wi-Fi enabled keypads are factory set to address 1 and cannot be changed.  Other keypads should be set to an ad-

Solution - Graphic Keypads

Figure 1: Wi-Fi Enabled Graphic Keypad

dress other than 1 when a Wi-Fi keypad is being used.  
Only 1 x Wi-Fi enabled keypad is supported per system.   

Dip Switch 5 has been provided on selected keypads to 
allow easy termination of the RS485 LAN at the keypad if 
required.

DIP Switch Address Select

4  5

SW5=LAN Term

i

Note

  Only 1 x Keypad can be assigned to each address.   

All Keypads are supplied from the factory set to  
address 1.  You must power cycle the panel or  
perform a LAN scan whenever you change the 
keypad address

DIP Switch  Address Settings

Keypad/

Reader N

o

S1

S2

S3

S4

S5

1

Off

Off

Off

Off

LAN T

er

mina

tor 

Swit

ch

2

On

Off

Off

Off

3

Off

On

Off

Off

4

On

On

Off

Off

5

Off

Off

On

Off

6

On

Off

On

Off

7

Off

On

On

Off

8

On

On

On

Off

9

Off

Off

Off

On

10

On

Off

Off

On

11

Off

On

Off

On

12

On

On

Off

On

13

Off

Off

On

On

14

On

Off

On

On

15

Off

On

On

On

16

On

On

On

On

Table 2: DIP Switch Address Settings

Figure 2: Address Switch Settings

Summary of Contents for CP799B

Page 1: ...curity System Installer Reference Guide EN Security Systems This guide covers the following keypads CP700B White CP710B Black CP722B Smart Card White CP732B Smart Card Black CP741B Wi Fi Enabled Tamper White CP799B Service Keypad ...

Page 2: ...ADDRESS SELECT 3 INSTALLING THE KEYPAD 4 KEYPAD OPERATION 5 LCD STATUS ICONS 5 KEYPAD KEY FUNCTIONS 5 HOLD DOWN FUNCTIONS 6 KEYPAD LED INDICATORS 6 KEYPAD ALERT TONES 7 EGRESS AND LOCK CONTROL 7 WI FI KEYPAD SETUP 8 CONFIGURATION EXAMPLES 9 BOX CONTENTS 9 SERVICE KEYPAD INSTALLER TOOL 10 ADDRESSING 10 CONNECTION DIAGRAM 11 SPECIFICATIONS 11 ...

Page 3: ...er 1 Only address 1 Table 1 Keypad Compatibility Keypad Addressing Each keypad fitted to the system must be assigned a unique address on the LAN For convenience the address dip switch configuration table shown below is also provided on the rear of the plastic keypad housing Wi Fi enabled keypads are factory set to address 1 and cannot be changed Other keypads should be set to an ad Solution Graphi...

Page 4: ...he required keypad address at this time Step 3 If the keypad has a built in tamper switch you will also need to install the rear tamper screw in the rear tamper plate Once installed use a knife to cut the 3 small plastic tabs holding the rear tamper plate so it is no longer connected to the keypad mounting plate Step 4 To mount the keypad simply align the 4 rectangular holes in the back of the key...

Page 5: ...ned All On or Part On On The area is turned All On or Part On Off The area is turned Off On All messages have been read Off Message queue is empty Flash An unread message is in the queue On Area is ready to turn on All On Part On Off Not ready Zone Open The Wi Fi enabled keypad or module has successfully connect ed to your local Wi Fi network The Wi Fi enabled keypad or module is not connected to ...

Page 6: ...larm If programmed the sirens will sound and the monitoring station will be notified Table 5 Hold Down Functions Figure 7 Keypad Emergency Alarm Triggers Keypad LED Indicators Keypads includes green blue and red LED s which pro vide visual feedback during system operation The green and red LED s indicators will show area and alarm status and the blue LED will show the door status depending how the...

Page 7: ...s nearly expired Entry Delay The hi lo entry delay warning tone will sound once every second when an en try delay zone in the area the keypad has been assigned to is triggered If the system is not disarmed before the entry time expires then an alarm will occur Error If you press an invalid button during any data entry sequence the keypad will sound a 2 second warning tone indicating that the comma...

Page 8: ...manual SSID Scan This option will request the system to create a list of all SSID s currently in range of the Wi Fi keypad Use the down arrow key to step through the available SSID s and press OK to select the required station The SSID scan also displays the signal strength for each station in dB s Decibels To ensure reliable Wi Fi per formance do not attempt to connect the keypad the a station wi...

Page 9: ... panel to send a trouble report when the control panel detects that the ethernet module is missing or when the module is rebooting for any reason A restore report will be sent when the control panel detects that the module has returned to normal Configuration Examples Alarm control function only 1 Install the keypad as per instructions 2 Set the home area for the keypad 3 Set keypad options as req...

Page 10: ...panel has been placed in service mode from one of the main keypads or if the panel cabinet tamper input is unsealed Service keypad operation will cease when service mode ends or the cabinet tamper is sealed The CP799B keypad includes a built in DF smart card reader allowing RFID cards and tokens to be easily enrolled di rectly at the keypad if required Alpha text characters have also been included...

Page 11: ... X X X ADDRESS ADDRESS ON 1 2 3 4 5 TAMPER Lock Output EGRESS INPUT N O BK RD WH BL YL GN TO DOOR LOCK 12V DF70 N O COM N C CM444 Relay Card RED BLACK WHITE BLUE YELLOW GREEN LAN LAN LAN A LAN B LOCK EGRESS Wiring Legend CM720B or CM723B Power Supply Battery backed up DOOR LOCK Egress Input ONLY USE THE SUPPLIED CONNECTION CABLE WHEN INSTALLING THE KEYPAD PROTECTION DIODE CM444B RELAY CARD MODULE ...

Page 12: ...Bosch Security Systems Level 2 21 Solent Circuit Baulkham Hills NSW 2153 Australia Phone 1300 026 724 www boschsecurity com au 2016 Bosch Security Systems Graphic Keypads BIRG Issue FTR1 0 ...

Reviews: