Graphic Keypads
Installer Reference Guide
9
Bosch Security Systems 03/16 Graphic Keypads BIRG FTR1.0
Default Gateway
Only enter when not using DHCP.
MAC Address
This location is read only and cannot be changed. The
MAC address of the Wi-Fi keypad is displayed here.
IP Options
Various IP options can be configured to allow the system
to display and or report IP related fault conditions.
Display Faults
Setting this option allows the keypad to display a
trouble condition if the control panel detects Wi-
Fi Keypad’s IP address has changed, if there is no IP
connection, if there is an IP lockout or an IP conflict.
Report Network Lost
Setting this option allows the control panel to report
when it detects that the Wi-Fi keypad can no longer
detect a Wi-Fi signal from the local wireless access
point.
Report IP Conflict
This option allows the control panel to report an IP
conflict via the dialler when it detects two computers
on the LAN or internet have been assigned the same
IP address.
Report Poll Fail
This option allows the control panel to report via the
dialler when the Wi-Fi keypad fails to send a poll to the
base station.
Report Module Missing
This option when set allows the control panel to send
a trouble report when the control panel detects that
the ethernet module is missing or when the module is
rebooting for any reason. A restore report will be sent
when the control panel detects that the module has
returned to normal.
Configuration Examples
Alarm control function only.
1) Install the keypad as per instructions.
2) Set the home area for the keypad.
3) Set keypad options as required remembering to dis-
able keypad emergency alarms and or single button
arming if the unit is being installed externally.
4) Assign users to the area.
Access control function only.
1) Install the keypad as per instructions.
2) Set the door assignment for the keypad.
3) Set keypad options as required.
4) Set output to door to operate door.
5) Set output event assignment.
6) Assign users to the access group.
Both Alarm and Access control functions.
1) Install the keypad as per instructions.
2) Set the home area for the keypad.
3) Set the door assignment for the keypad.
4) Set keypad options as required remembering to dis-
able keypad emergency alarms and or single button
arming if the unit is being installed externally.
5) Set output to access group to operate door.
6) Set output event assignment.
7) Assign users to the area.
8) Assign users to the access group.
Box Contents
Keypads are supplied with the following parts.
Keypad Main Unit With Door
Keypad Mounting Plate
Instruction Sheet
Emergency Key Sticker