6 720 820 872 (2016/12)
CR 400 | CW 400 | CW 800
16 | Basic principles of operation
4.2
Overview of the symbols in the display
Fig. 14
Example for a standard display of a system with more than one heating circuit
Æ
Fig. 14, page 16
Item
Symbol
Designation
Explanation
1
Value display
Display of current temperature:
•
Room temperature for wall-mounted installation
•
Heat source temperature for installation in heat source.
2
–
Information line
Display of time of day, day of the week and date.
3
Additional
temperature
display
Display of an additional temperature: outside temperature, temperature of the
solar collector or a DHW system (for further information
Æ
operating instructions
of the user interface).
4
–
Text information
E.g. the designation of the temperature currently displayed (
Æ
Fig. 14, [1]); a
designation for the room temperature is not displayed. If a fault is present,
corresponding information will be displayed here until the fault has been
rectified.
5
Information
graphic
Solar pump is in operation.
DHW heating is active
DHW heating is switched off
Burner is on (flame)
B
Heat source is blocked (e.g. by an alternative heat source).
6
Time program
Graphical display of the active time program for the heating circuit displayed. The
height of the bars represents roughly the desired room temperature in the
different time slots.
7
Time marker
The time marker
indicates the current time of day in the time program in
15 minute increments (= division of time scale).
Table 6 Symbols on the standard display
6
1
3
8
2
9
4
5
7