6 720 820 872 (2016/12)
CR 400 | CW 400 | CW 800
Service menu | 33
Use minimum value
Yes
A C 400/C 800 user interface in combination with a CR 10 or CR 100
remote control is installed in the living space. The heating system is
operated according to the lower room temperature value (measured at the
internal temperature sensor at both user interfaces) (e.g. in large rooms in
order to reliably record the room temperature with room temperature-
dependent control, room frost protection, room influence, ...).
No
A C 400/C 800 user interface in combination with a CR 10 or CR 100
remote control is installed in the living space. The heating is always
operated according to the room temperature value of the remote control.
Heating system heat
circ. 1
Radiator
Factory default of the heating curve according to heating type, e.g.
curvature and design temperature
Convector heater
Underfloor
Set point constant
30 ...
75
... 85 °C
Flow temperature for constant heating circuit (only available with Constant
control type)
Max. flow
temperature
30 ...
75
... 85 °C
The maximum flow temperature can only be adjusted with a room-
temperature dependent control type (section of the heating curve with
weather-compensated control). The adjustment range depends on the
selected heating system.
Set heating curve
Fine adjustment of the heating curve that is preset via the heating system
(
Æ
Set the heating system and heating curves for weather-compensated
control, page 35)
Setback type
Reduced mode
Further information on the setback type for the selected heating circuit
(
Æ
Setback types, page 38)
Outside temperature
threshold
Room temperature
threshold
Reduced mode
below
– 20 ...
5
... 10 °C
Temperature for the setback type Outside temperature threshold
(
Æ
Setback types, page 38)
Heat constantly
below
Off
The heating system operates independent from the the adjusted outside
temperature in the active operating mode (
Æ
Heat constantly below a
certain outside temperature, page 38).
– 30 ... 10 °C
If the adjusted outside temperature falls below the value set here, the
heating system automatically changes from the setback mode to the heating
mode (
Æ
Heat constantly below a certain outside temperature, page 38).
Outdoor temp.
Notice
: to ensure frost protection for a constant heating circuit or the entire
heating system, set outside temperature-dependent frost protection. This
setting is independent of the set control type.
Room and outdoor temp.
Frost protection is deactivated/activated on the basis of the temperature
selected here (
Æ
Frost protection limit temperature (outside temperature
threshold), page 39)
Room temperature
Frost protect
Off
Frost protection off
Frost prot. limit
temp.
– 20 ...
5
... 10 °C
Æ
Frost protection limit temperature (outside temperature threshold),
page 39
Mixer
Yes
Selected heating circuit with mixer
No
Selected heating circuit without mixer
Menu item
Adjustment range
Description
Table 15 Check settings in the menu Heating circuit 1 ... 8