6 720 820 872 (2016/12)
CR 400 | CW 400 | CW 800
Service menu | 41
Fig. 25
Screed drying process with default settings
t
Time in days
T
VL
Flow temperature
7.2
DHW settings
Fig. 26
DHW settings menu
DHW system I ... II
Settings of the DHW systems can be adapted in this menu. For
instance, the maximum DHW temperature that can be specified
by the user and whether or not there is circulation in the DHW
system is set here. The time and the temperature for the
thermal disinfection are also set here.
6720 645 480-31.2O
20°C
30°C
40°C
50°C
60°C
1
0
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22
t
T
VL
2
3
1
6
5
4
7
6 720 815 238-03.1O
WARNING:
Risk of scalding!
The maximum DHW temperature (
Max. DHW
temp.
) can be set above 60 °C and during
thermal disinfection the DHW is heated to
above 60 °C.
▶ Inform all people concerned and make
sure that a mixer is installed.
Menu item
Adjustment range Description
DHW system I
install. (DHW
system II install.)
No
DHW system not installed
At the boiler
Electrical assemblies and components for the selected DHW cylinder are directly
connected to the heat source (only available with DHW system I)
At the module
Electrical assemblies and components for the selected DHW cylinder are connected to
the MS 100/MS 200 or MM 100/MM 200 modules
Config. DHW at
boiler
Hydraulic connection DHW system I to heat source (boiler).
No DHW
No DHW system installed
3-way valve
DHW system I is supplied via 3-way valve
Primary pump
DHW system I is supplied via cylinder primary pump
Max. DHW temp.
60
... 80 °C
Maximum DHW temperature in the selected DHW cylinder
DHW
e.g. 15 ...
60 °C
(80 °C)
Required DHW temperature for the DHW operating mode; the adjustment range
depends on the installed heat source.
Table 19 Settings in the DHW system I ... II