Part IV: Multi-Area Use
Working with Multiple Areas from a Single Command Center
D1260 Owner’s Manual
© 2003 Bosch Security Systems
50410C
Part IV: Multi-Area Use
Working with Multiple Areas from a Single Command Center
Each of the functions described in the preceding section on Advanced Commands is presented as though your system
includes only one area. If your system includes more than one area, it can be set up in one of two ways by the installing
company:
1.
Each command center will only have access to the local area to which it is assigned, or
2.
Each command center may access either some or all areas beyond the one to which it is assigned. This factor
is referred to hereafter as
command center scope
.
If your command center allows access to areas other than the local area (that is to say, has scope in other areas), then the
command center will limit your access to those areas within the command center scope and for which your personal
passcode has authority.
Given that you have access to areas beyond the local area, the means of accessing the various system functions depends
upon the specific function.
For some functions, the command center allows you to select the area (or point) in which to perform the function. These
“selectable” functions are:
•
DISARM ?,
•
MASTER ARM AREA ?.
•
BYPASS A POINT? and
•
UNBYPASS A POINT?
Another group of functions may automatically work in all areas in which you have passcode authority and which are
within the scope of the command center. These are:
•
Turning On Multiple Areas with a Passcode,
•
Turning Off Multiple Areas with a Passcode,
•
DISARM ALL ?,
•
MASTER ARM ALL?,
•
VIEW MEMORY?,
•
WALK TEST?,
•
RESET SENSORS ?,
•
ADD PASSCODES ?,
•
FIRE TEST?,
•
VIEW POINT STATUS? and
•
VIEW AREA STATUS?.
Some functions may be area-specific. To perform these functions, you must first use the MOVE TO AREA ? function
(Command 50) to gain access to the desired area. Once in the desired area you can perform the functions you wish.
Area-specific functions include:
•
PERIMETR INST? (Perimeter On Instant),
•
PERIMETR DELAY ? (Perimeter On Delay),
•
PERIMETR PART ? (Perimeter On Partial),
•
EXTEND CLOSING ?,
•
WATCH MODE ?,
•
COMMAND 7 ?,
•
COMMAND 9 ? and
•
CHG DISPLAY ?.
A last group of functions don’t relate to specific areas and are thus system-wide. These are:
•
SEND REPORT?,
•
REMOTE PROG ?,
•
CHG TIME/DATE ?,
•
CHG SKEDS ?,
•
DEL PASSCODES ?,
•
CHG RELAYS ?,
•
CHG PASSCODES ?,
•
PRINT LOG ? and
•
VIEW LOG?
Summary of Contents for D1260 Series
Page 2: ...D1260 Owner s Manual 50410C 2003 Bosch Security Systems ...
Page 4: ...Contents D1260 Owner s Manual 50410C 2003 Bosch Security Systems ...
Page 144: ...Appendix Passcode Worksheet D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Page 154: ...D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...