Appendix
Security System Glossary
D1260 Owner’s Manual
© 2003 Bosch Security Systems
50410C
Security System Glossary
Area
A group of detection devices connected to your security system.
Arm
To turn on your controlled points (burglar detection devices). When an area is armed
and a controlled point trips, an alarm occurs or entry delay begins. When an area is
disarmed, faulting controlled points does not generate alarms.
Authority Level
Your security company or security representative assigns an authority level to your
passcode. The authority level determines what command center functions you can
execute.
Bypass
Selectively remove points from the security system. You might bypass a point in order
to arm the perimeter with a window open.
Central Station
A facility where trained personnel monitor your security system 24 hours a day. Your
security system may be programmed to contact the central station during alarm
conditions, enabling central station personnel to dispatch the proper authorities.
Closing Report
A report your system can be programmed to send to the central station indicating that
an area has been armed. Opening and closing reports are commonly used by
commercial accounts.
Command Menu
A list of functions programmed by your security company. They can perform most
command center functions with only two or three keystrokes.
Entry Delay
A programmed delay of system alarm response, which allows you to enter an armed
area through the correct point and disarm the area. If you don’t disarm before the
delay time expires, the system begins an alarm response, which may include reports to
the central station.
Exit Delay
A programmed delay of system alarm response, which allows you to exit after arming
an area. If you don’t exit before the delay time expires, entry delay begins. You must
disarm the system. If you don’t disarm before the delay time expires, the system
begins an alarm response, which may include reports to the central station.
Faulted Point
A point that is not normal (a door or window is open).
Force Arm
To turn on (arm) the security system even though one or more points are faulted.
Force arming bypasses the faulted points.
Idle Text
The security system displays idle text at command centers when it is not performing a
user-requested function. Idle text shows the arming status of the system.
Master Arm
To turn on (arm) both interior points and perimeter points.
Menu
A list of functions you execute from a command center.
Opening Report
A report your system can be programmed to send to the central station indicating that
an area has been disarmed. Opening and closing reports are commonly used by
commercial accounts.
Perimeter Arm
An arming command that arms only the perimeter points.
Point
A detection device or group of devices connected to your security system. Points
display individually at the command center with custom text. The text can describe a
single door, motion sensor, smoke detector, or an area such as UPSTAIRS or
GARAGE.
Relay
Your system may have relays programmed to provide control of devices such as
premises lighting or entry gates. Your security company programs relays for automatic
control and/or control from your command center.
Trouble
A service condition that needs to be corrected, such as a broken wire
Summary of Contents for D1260 Series
Page 2: ...D1260 Owner s Manual 50410C 2003 Bosch Security Systems ...
Page 4: ...Contents D1260 Owner s Manual 50410C 2003 Bosch Security Systems ...
Page 144: ...Appendix Passcode Worksheet D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...
Page 154: ...D1260 Owner s Manual 50410C 2003 Bosch Security Systems Notes ...