Part II: System Commands
MASTER ARM INST ? (C 1 + 1)
D1260 Owner’s Manual
© 2003 Bosch Security Systems
50410C
MASTER ARM INST ? (C 1 + 1)
Use this function to turn on a single area, both perimeter and interior without delays. When entering COMMAND 11,
remember that the second 1 must be pressed within 2 seconds after pressing the first 1.
The menu entry
MASTER ARM INST>
is different in that it allows all or selected areas to be armed instantly.
Note:
COMMAND 11 does not comply with SIA CP-01 Standard.
Note:
Using the C 1 + 1 shortcut will only instantly arm the area where the keypad has been assigned.
Example, if the D1260 is assigned to Area 1, only Area 1 will be armed when C 1 + 1 is pressed.
1.
The display shows disarmed idle text.
2.
Press the
COMMAND
key. The display shows
*System
Command*
.
3.
Press the
1
key. Now press the
1
key again.
+
4.
The command center display shows
AREA 1
WAREHOUSE All On Instant
.
5.
To disarm your security system, enter your personal
passcode and press
ENTER
.