Installation Guide | 7.0   Assigning a device address 

 

 

Bosch Security Systems | 8/04 | 44677G 

 

 

Figure 8:  6-position DIP switch (Module address 

2 is shown) 

O

N

1

2

3

4

5

6

 

 

 

 

 

 

 

Table 2:  Keypad address assignments and DIP 

switch settings 

 

 

DIP Switch Settings 

DIP 
Switches 

S1 S2 S3 S4 S5 

S6 

Module 
Address 

1 2 4 8 16 

MODE

0* 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

ON  OFF OFF OFF OFF 

ON 

OFF 

ON 

OFF 

OFF 

OFF 

ON 

ON ON OFF OFF OFF 

ON 

OFF 

OFF 

ON 

OFF 

OFF 

ON 

ON  OFF ON  OFF OFF 

ON 

OFF 

ON 

ON 

OFF 

OFF 

ON 

ON ON ON OFF OFF 

ON 

OFF 

OFF 

OFF 

ON 

OFF 

ON 

ON OFF OFF ON OFF 

ON 

10 

OFF 

ON 

OFF 

ON 

OFF 

ON 

11 

ON ON OFF ON OFF 

ON 

12 

OFF 

OFF 

ON 

ON 

OFF 

ON 

13 

ON OFF ON ON OFF 

ON 

14 

OFF 

ON 

ON 

ON 

OFF 

ON 

15 

ON ON ON ON OFF 

ON 

16 

OFF 

OFF 

OFF 

OFF 

ON 

ON 

*   Address 0 is reserved for the Installer’s keypad. This keypad is 

not intended for permanent installation. See the control panel’s 
installation instructions for more details on the Installer’s 
keypad. 

 

 

 

Table 2:  Keypad address assignments and DIP 

switch settings (continued) 

 

 

DIP Switch Settings 

DIP 
Switches 

S1 S2 S3 S4 S5 

S6 

Module 
Address 

1 2 4 8 16 

MODE

17 

ON 

OFF 

OFF 

OFF 

ON 

ON 

18 

OFF 

ON 

OFF 

OFF 

ON 

ON 

19 

ON 

ON 

OFF 

OFF 

ON 

ON 

20 

OFF 

OFF 

ON 

OFF 

ON 

ON 

21 

ON 

OFF 

ON 

OFF 

ON 

ON 

22 

OFF 

ON 

ON 

OFF 

ON 

ON 

23 

ON 

ON 

ON 

OFF 

ON 

ON 

24 

OFF 

OFF 

OFF 

ON 

ON 

ON 

25 

ON 

OFF 

OFF 

ON 

ON 

ON 

26 

OFF 

ON 

OFF 

ON 

ON 

ON 

27 

ON 

ON 

OFF 

ON 

ON 

ON 

28 

OFF 

OFF 

ON 

ON 

ON 

ON 

29 

ON 

OFF 

ON 

ON 

ON 

ON 

30 

OFF 

ON 

ON 

ON 

ON 

ON 

31 

ON 

ON 

ON 

ON 

ON 

ON 

32 

OFF 

OFF 

OFF 

OFF 

OFF 

ON 

 

Summary of Contents for D621 Series

Page 1: ...EN Installation Guide Keypads D600 Series ...

Page 2: ...have an armed status indicator three programmable emergency keys and a built in sounder that emits several distinct tones The D623 D623W D623B and D625 D625W D625B can be used for local programming of a compatible control panel The control panel supplies all power and data requirements for keypads using a simple four wire connection Depending on the control panel a maximum of eight keypads can be ...

Page 3: ...igerated areas outdoors or areas where the temperature can drop below 0 C 32 F or areas of extreme heat 50 C 122 F Do not mount any of the D600 Series in locations that are exposed to direct sunlight This makes the display less visible and can damage keypad components You can mount the keypads on a flat wall or on the following Bosch Security Systems accessories The D54B and D54C mounting kits wil...

Page 4: ...3 D623W D623B 305 m 1000 ft 310 m 2000 ft control panel to D625 D625W D625B 69 m 225 ft 183 m 600 ft control panel to D600 Series using an External Power Supply 305 m 1000 ft 310 m 2000 ft Due to higher current requirements for the D625 D625W D625B Vacuum Fluorescent Keypad the wire lengths shown must be used when wiring from the control panel Wire length may be restricted by panel limitations Ref...

Page 5: ... 7 0 Assigning a device address Each time you change the address switches you must cycle the power to the keypad turn the power off and then on for the address change to take effect Figure 7 Inside view of keypad O N 1 2 3 4 5 6 1 2 3 4 5 6 7 1 LCD display D623 D623W D623B LED display D621 D621W D621B or vacuum florescent display D625 D625WD625B 2 Keypad 3 Wire opening 4 Data wire connector 5 6 po...

Page 6: ...FF ON 13 ON OFF ON ON OFF ON 14 OFF ON ON ON OFF ON 15 ON ON ON ON OFF ON 16 OFF OFF OFF OFF ON ON Address 0 is reserved for the Installer s keypad This keypad is not intended for permanent installation See the control panel s installation instructions for more details on the Installer s keypad Table 2 Keypad address assignments and DIP switch settings continued DIP Switch Settings DIP Switches S1...

Page 7: ...0 Series Specifications Operating Voltage Nominal 12 VDC supplied by control panel s auxiliary power supply Maximum 115 mA Normal 35 mA D621 D621W D621B Standby 35 mA Maximum 100 mA Normal 100 mA D623 D623W D623B Standby 100 mA Maximum 270 mA Normal 270 mA Current Requirements D625 D625W D625B Standby 270 mA Enclosure Dimensions H x W x D 11 6 cm x 20 7 cm x 2 1 cm 4 56 in x 8 15 in x 0 816 in Col...

Page 8: ... 2004 Bosch Security Systems 44677G Bosch Security Systems 130 Perinton Parkway Fairport NY 14450 9199 Customer Service 800 289 0096 Technical Support 888 886 6189 ...

Reviews: