D9131A

Overview

 D9131A User's Guide 

34584G

Page 4

© 2002 Bosch Security Systems

 

Text

Usually this is programmed by your alarm technician, however, the following text is not:

SDI XX

- Event reported was initiated by the Serial Device Interface indicated. The numbers 1 through 8 indicate the

event is from one of the supervised command centers. The numbers 17, 18 or 19 indicate the event is from a printer.
Numbers 33 to 40 indicate the event is from the Access Control Module.

(The following text indicates previous armed status.)

Was Master Armed

Was Perim Delay

Was Perim Instant

Was Disarmed

Was Mstr Instnt

 

User Text

Your alarm technician usually will program this. User text is printed whenever an event with a User ID is noted.

Summary of Contents for D9131A

Page 1: ...Parallel Printer Interface Module D9131A User s Guide ...

Page 2: ...D9131A D9131A User s Guide 34584G Page 2 2002 Bosch Security Systems ...

Page 3: ... a Print Log command that allows you to print the entire history of events stored in your system or you may select to print only events that have occurred from a specific date forward 1 3 Printing Format Your security system prints events with top and bottom margins and form feed between pages with descriptive headers Each event is printed on two lines The first line contains the time and date the...

Page 4: ...1 through 8 indicate the event is from one of the supervised command centers The numbers 17 18 or 19 indicate the event is from a printer Numbers 33 to 40 indicate the event is from the Access Control Module The following text indicates previous armed status Was Master Armed Was Perim Delay Was Perim Instant Was Disarmed Was Mstr Instnt User Text Your alarm technician usually will program this Use...

Page 5: ...ted Closing Report User with reported ID armed area Comm Failure Security system could not communicate using the phone number reported Call for service Date Changed User with reported ID changed the date in the security system Door Closed Restoral An access door in the area specified restored to normal after a Door Left Open event has occurred Door Cycled An access door in the area specified was c...

Page 6: ...An access card holder attempted access but was denied due to the user s authority level No Entry Interlk Access was denied due to the interlock door being open No Entry Secured Access was denied due to the door being secured No Entry Unknown Access was denied because the user was not found in the database Opening Report User with reported ID disarmed area Params Changed Security system programming...

Page 7: ...s report opening at area specified S Perim Delay Status report area perimeter specified is armed with entry exit delay S Perim Instant Status report area perimeter specified is armed no delay S Supervision Status report Supervision at area specified S Trouble Status report trouble at area specified SDI Failure Serial Device Interface specified is not reporting 1 8 command centers 017 018 019 print...

Page 8: ...al alarm in the area specified Usr Code Change User ID specified was changed Usr Code Delete User ID specified was deleted User Level Set The authority level of the specified user has been modified User Tamper User with wrong ID tried to access specified area Walk End Walk test in area specified is complete Walk Start A walk test is in progress in the area specified Was Force Armed User with the r...

Reviews: