D9131A

Event Description and Troubleshooting

 D9131A User's Guide 

© 2002 Bosch Security Systems

Page 5

34584G

2.0

Event Descriptions and Troubleshooting

The following events and their respective descriptions are listed in alphabetical order. Your system may not display all
of the events. For detail in the cause of events, see your 

Security System

 

Owner’s Manual

.

Event

Description

Access Granted

A card access holder has been granted access at the point specified.

AC Failure

AC power to the security system is interrupted. Check the plug-in transformer and the
circuit breaker.

AC Restoral

AC power to the security system has been restored.

ALARM

-

Door Open

An access door has been held open beyond the allowed time while the area was armed.

Alarm Report

Alarm at device in area specified. This event also reports Cross Point Alarms, including
Cross Group (CG:##) information.

All Points
Tested

All points have been tested while in the Service Walk Test, Fire Walk Test, or Walk Test
mode.

Bad Call To RAM

System tried to call Remote Account To Ram Manager (RAM) and failed. Call your security
company.

Battery Low

Security system battery is low. Replace the battery.

Battery Missing

Security system battery is disconnected or has discharged. Reconnect the battery; call for
service.

Battery Restore

Security system battery has recharged.

Cancel Alarm

User with reported ID canceled an alarm from the area specified.

Card Assigned

An access card/token was added to the system.

Command Bypass

Device specified is bypassed.* System will not respond to faults at this point.

Closing Early

User armed area earlier than expected.

Closing Late

User armed area later than expected.

Closing Report

User with reported ID armed area.

Comm Failure

Security system could not communicate using the phone number reported. Call for service.

Date Changed

User with reported ID changed the date in the security system.

Door Closed-
Restoral

An access door in the area specified restored to normal after a 

Door Left Open

 event

has occurred.

Door Cycled

An access door in the area specified was cycled.

Door Left Open

The door specified has been left open past the programmed time.

Door Locked

An access door in the area specified was locked for normal operation.

Door Secured

An access door in the area specified was secured, which prohibits access.

Door Unlocked

An access door in the area specified was unlocked allowing free access.

Duress

User with reported ID manually initiated a special alarm in the area specified.

Early to Open

User disarmed area earlier than expected. If the entire security system is being disarmed,
the previous state of security system is indicated. If just one area is being disarmed, no
previous status is indicated.

Extra Point

Area specified reports an unprogrammed device. Call for service.

Extn Close Time

User with reported ID extended area’s closing time to that specified.

Fail To Close

Area failed to arm within your programmed closing window.

Fail To Open

Area failed to disarm within your programmed opening window.

F Close Early

User with reported ID force armed* specified area later than expected.

F Close Late

User with reported ID force armed* specified area later than expected.

F Close Pr Dlay

User with reported ID force armed* perimeter with entry/exit delay.

F Close Pr Inst

User with reported ID force armed* area perimeter with no delay time.

Fire Alarm

Fire Alarm at device specified.

Fire Cancel

See 

Cancel Alarm.

Fire Restoral

The fire trouble or alarm event at the device specified has been restored.

Summary of Contents for D9131A

Page 1: ...Parallel Printer Interface Module D9131A User s Guide ...

Page 2: ...D9131A D9131A User s Guide 34584G Page 2 2002 Bosch Security Systems ...

Page 3: ... a Print Log command that allows you to print the entire history of events stored in your system or you may select to print only events that have occurred from a specific date forward 1 3 Printing Format Your security system prints events with top and bottom margins and form feed between pages with descriptive headers Each event is printed on two lines The first line contains the time and date the...

Page 4: ...1 through 8 indicate the event is from one of the supervised command centers The numbers 17 18 or 19 indicate the event is from a printer Numbers 33 to 40 indicate the event is from the Access Control Module The following text indicates previous armed status Was Master Armed Was Perim Delay Was Perim Instant Was Disarmed Was Mstr Instnt User Text Your alarm technician usually will program this Use...

Page 5: ...ted Closing Report User with reported ID armed area Comm Failure Security system could not communicate using the phone number reported Call for service Date Changed User with reported ID changed the date in the security system Door Closed Restoral An access door in the area specified restored to normal after a Door Left Open event has occurred Door Cycled An access door in the area specified was c...

Page 6: ...An access card holder attempted access but was denied due to the user s authority level No Entry Interlk Access was denied due to the interlock door being open No Entry Secured Access was denied due to the door being secured No Entry Unknown Access was denied because the user was not found in the database Opening Report User with reported ID disarmed area Params Changed Security system programming...

Page 7: ...s report opening at area specified S Perim Delay Status report area perimeter specified is armed with entry exit delay S Perim Instant Status report area perimeter specified is armed no delay S Supervision Status report Supervision at area specified S Trouble Status report trouble at area specified SDI Failure Serial Device Interface specified is not reporting 1 8 command centers 017 018 019 print...

Page 8: ...al alarm in the area specified Usr Code Change User ID specified was changed Usr Code Delete User ID specified was deleted User Level Set The authority level of the specified user has been modified User Tamper User with wrong ID tried to access specified area Walk End Walk test in area specified is complete Walk Start A walk test is in progress in the area specified Was Force Armed User with the r...

Reviews: