Bosch Security Systems | 2007-11 | 9922 141 70691 en
DCN Wireless
| Installation and User Instructions | System Design and Planning
en
| 17
3.5.3
Power supply
The CCU supplies power for:
•
the optical network, and
•
the units connected via the DCN cables.
Refer to figure 3.1.
If more power is necessary, you must install external
power supplies in the optical network. The devices
below can connect to external power supplies:
•
LBB4410/00 Network Splitter (refer to the DCN
Next Generation Installation and User Instructions).
•
LBB4414/10 Fiber Interface (refer to the DCN Next
Generation Installation and User Instruction).
3.5.4
Overload indication
Each optical network socket of the central control unit
has a red LED that comes on to show that there is a
power overload. An overload occurs when the
necessary power for the devices is greater than that
supplied. The sockets are deactivated and the devices
connected to the central control unit do not operate.
The socket checks every 8 seconds for power overloads.
3.6 Cabling
3.6.1
Introduction
Many devices in the optical network have two optical
network sockets that are interchangeable. You can use
the two optical network sockets to make a redundant
ring.
3.6.2
Definitions
The optical network uses two types of cable:
•
POF
Plastic Optical Fiber.
•
GOF
Glass Optical Fiber.
figure 3.1: Optical network power supply
OK
Fault
Fault
RS 232
Network
1
2
Audio In 1
Audio Out 1
Audio In 2
Audio Out 2
Mains
Port 2
115: 100-120V
50-60Hz
T2.5A 250V
230: 220-240V
50-60Hz
T2A H 250V
RS 232
Port 1
Trunk
1
2
230
P < 65 W
DCN-WCCU
DCN-WCCU
DCN-WCCU
P < 65 W
P < 130 W
OK
Fault
Fault
RS 232
Network
1
2
Audio In 1
Audio Out 1
Audio In 2
Audio Out 2
Mains
Port 2
115: 100-120V
50-60Hz
T2.5A 250V
230: 220-240V
50-60Hz
T2A H 250V
RS 232
Port 1
Trunk
1
2
230
OK
Fault
Fault
RS 232
Network
1
2
Audio In 1
Audio Out 1
Audio In 2
Audio Out 2
Mains
Port 2
115: 100-120V
50-60Hz
T2.5A 250V
230: 220-240V
50-60Hz
T2A H 250V
RS 232
Port 1
Trunk
1
2
230
Note
If only one of the optical network sockets has a
power overload, the two overload LEDs come
on.