16
DCN-WLIION Battery
Pack
16.1 Introduction
The DCN-WLIION Battery pack is used with the
wireless devices (refer to table 16.4).
16.2 Safety
table 16.1: Battery capacity
Output voltage:
7.2 V(DC)
Capacity:
4600 mAh
Life time:
500 charge-discharge cycles
Charge time:
3 hours
Caution
Use the DCN-WCH05 Battery Charger to
charge DCN-WLION Battery Packs.
table 16.2: Compatible devices
Type
Description
DCN-WD
Wireless Discussion Unit
DCN-WDD
Wireless Discussion Unit
DCN-WDV
Wireless Discussion Unit
figure 16.1: Safety instructions
CAUTION Important Safety Instructions for Li-ion batteries.
Do not short-circuit the battery.
Do not pierce or crush the battery.
Do not disassemble or modify the battery.
Do not heat, incinerate or expose the battery to direct continuous sunshine.
Do not immerse the battery in any liquid it may be vent or rupture.
Respect charging, discharging, transport and storage instructions.
Charge the battery between 0 ºC and 45 ºC (32ºF and 113ºF).
Discharge the battery between -20 ºC and 60 ºC (-4ºF and 140ºF).
Rated : 7.2V
4800 mAh
Charging Current : 12V/2.5A
DCN-WLIION-D
Rechargeable Lithium-ion Battery Pack
NL-4827HG-10
S/N:
SMYYWW9999
Li-ion
US ITE ACCESORY
C
LISTED
19JW
M
04