DCN Wireless 2.32 Release Notes
en | 5
Bosch Communications Systems
2
Release 2.32
2.1
General
2.1.1
Release
September 1st 2007.
2.1.2
Firmware/FPGA versions
Product
FPGA
SW FW
DCN-WCCU 2.18 2.32.1618 4.00.2075
DCN-WDxx 1.02 --
--
DCN-WAP 1.02 2.32.0161
--
DCN-DDB -- 1.4.XXXX
--
DCN-DDI 2.0 --
--
DCN-FCS 2.5 --
--
DCN-IDESK 1.3 1.30.XXXX
--
DCN-SWSMV --
1.21.0197 --
INT-TX04 2.2.0
--
4.30.2233
INT-TX08 2.2.0
--
4.30.2233
INT-TX16 2.2.0
--
4.30.2233
INT-TX32 2.2.0
--
4.30.2233
LBB 4402/00
--
--
4.30.2233
LBB 4404/00
--
--
4.30.2233
PRS-4DEX4 --
--
4.30.2233
2.2
Compatibility restrictions
The following versions are not compatible with this
release:
2.2.1
DCN-IDESK
Product
FPGA SW
FW
DCN-IDESK 1.1 --
--
2.2.2
DCN-SWSMV
DCN-SWSMV < 1.1 is not compatible with DCN
Wireless
2.2.3
DCN-MICS and DCN-MICL
Pluggable microphones < HW version 03.00 can
cause hum in DCN-Wireless system.
Pluggable Microphones with HW version
≥
03.00
must be used, these can be recognized by marking
dot on connector, see picture below.
2.2.4
DCN-WAP
It’s not possible to upgrade a DCN-WAP HW-
version <1.20 with the Download & License Tool
version 2.32. To solve this, contact the Bosch
Service Channel and ask to exchange your DCN-
WAP for a DCN-WAP with HW-version
≥
1.20.
2.2.5
DCN-WAP & DCN-WCCU
DCN-WAP HW-version
≥
1.20 is not compatible
with DCN-WCCU with SW-version < 2.32.
Instructions: In case a DCN-WAP with HW-version
≥
1.20 is connected with a DCN-WCCU with SW-
version < 2.32:
•
The LEDs on the DCN-WAP will be; Off –
Flashing (slow) – Off (Refer to this release
notes, chapter 2.3.2, third bullet)
•
The DCN-WCCU will show ‘Incompatible
SW’. (Refer to table 10.21 of the Installation
& User Instructions)
To solve this, use the Download & License Tool
version 2.32 to upgrade the DCN-WCCU to version
2.32.
DCN-WCCU with SW-version
≥
2.32 is not
compatible with DCN-WAP with HW-version < 1.20.
Instructions: In case a DCN-WCCU with SW-version
≥
2.32 is connected with a DCN-WAP with HW-
version < 1.20:
•
All LEDs on the DCN-WAP will be ‘on’
(Refer to table 11.4 of the Installation &
User Instructions)
•
The DCN-WCCU will show ‘Incompatible
SW’. (Refer to table 10.21 of the Installation
& User Instructions)
To solve this, contact the Bosch Service Channel
and ask to exchange your DCN-WAP for a DCN-
WAP with HW-version
≥
1.20.
Or, use the Download & License Tool version 2.31
to downgrade the DCN-WCCU to version 2.31.
2.3
Errata
2.3.1
Integrus manual: added menu 4B Network
mode
Menu 4B (Network mode) has been added.
Options:
•
Automatic – use this when the transmitter is not
used in combination with DCN Next Generation
or DCN wireless.
•
Enabled – use this when the transmitter is
exclusively used in combination with DCN Next
Generation or DCN wireless.
When the Integrus transmitter is alternately used in
combination with and without DCN Next Generation
or DCN wireless, then you can use the automatic
mode. In that case take care that the transmitter is
switched on after the other equipment in the DCN
Next Generation or DCN wireless system is
switched on, else unwanted behavior can occur.