17 | Recording and Telemetry
126 / 188
DDU 10
Bosch Motorsport
Bit
Value
Name
1
2
DATAOK
2
4
BLKOK
3
8
-
4
16
-
5
32
-
6
64
STARTED
7
128
-
Content of status bits
Name
Bitset
Bit cleared
RECORD
Measurement data is re-
corded.
No measurement data will be stored because meas-
urement thresholds are not reached.
DATAOK
Received data without
error.
Discarding received data because of wrong
timestamps. Check wiring of SYNC signal.
BLKOK
All measurement blocks
have been set up cor-
rectly.
Some measurement blocks have not been set up
correctly.
STARTED
A measurement has
been set up.
A measurement is not set up. Either no recording
configuration has been found or logger software
upgrade is not activated.
17.2.5 Displaying online recording diagnosis
("statectrl_ok")
1.
To add a Recording Diagnosis element to a measurement sheet, drag a ‘Bit-LED’ ele-
ment from the Toolbox and drop it on measurement sheet.
2.
Drag channel ‘statectrl_ok’ from the Data Area and drop it on the ‘Bit-LED’ element.
The ‘Bit-LED’ element shows the state of received channel data in bit-representation. A
green highlighted channel means 0, a red highlighted channel means 1.
– Measurement correctly initialized, but recording threshold(s) not reached: 254
– Measurement correctly initialized, DDU 10 is recording data: 255
– Values less than 254 indicate an error state