20 | Lap Trigger
166 / 188
DDU 10
Bosch Motorsport
20.2 Counting outing/laps/fragments
Functionality
– Power ON: measurement is initialized but not yet started
– Global start condition fulfilled: recording starts
– Reception of valid lap trigger: recording of lap completed, new lap starts
– Power OFF or Global start condition not fulfilled: recording of lap completed, system
shutdown
The system is counting:
Outing:
– The outing counter is incremented with each power cycle when at least one valid lap
(not by forced lap trigger) was recorded
Lap:
– Leaving the pits to lap trigger
– Lap trigger to lap trigger
– Enforced lap trigger (see Distance based forced trigger [
}
168])
Fragment:
– Test bench operation
– Power cycle on track or box (e.g. engine stalled)
– File fragmentation size [MB], time [sec]
Channels for display
To display counters use the following channels:
Channel
Function
Laptrigger_outcnt_dls
Outing counter
Laptrigger_lapctr_dls
Lap counter
Fractr
Fragment counter
Counting in WinDarab
To automatically name recorded files use filename templates in WinDarab dialog:
Filename template
Function
[outing]
Value of outing counter
[lap]
Value of lap counter
[fragment]
Value of fragment counter