10.6
Configuring PWM outputs
PWM
–
Pulse Width Modulation
–
Output frequency is constant
–
‘On time’ (duty cycle) controlled by input channel
DDU 7 has 4 PWM outputs
–
Low-side switch
–
Up to 2 A each
–
Selectable output frequency
–
Duty cycle controlled by characteristic curve
U
out
Time
Output frequency
Duty cycle 20%
(switch closed)
Output frequency
Time
U
out
Duty cycle 80%
10.6.1
Configuring a PWM output
1.
Click on ‘Measurement Sources’ in the Toolbox.
2.
Drag the ‘PWM Out’ computed source from the Toolbox and drop it on the desired
‘PWM_OUT’ channel in the DDU 7 Project Tree.
3.
A ‘PWM Out Wizard’ opens.