background image

 

WARNING - TO REDUCE THE

RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OB-
SERVE THE FOLLOWING:

A. Installation work and electrical wir-

ing  must be done by qualified

person(s) in accordance with all ap-

plicable codes & standards, including

fire-rated construction.

B. Sufficient air is needed for proper

combustion and exhausting of gases

through the flue (chimney) of fuel

burning equipment to prevent back

drafting.    Follow the heating equip-

ment manufacturers guideline and

safety standards such as those pub-

lished by the National Fire Protection

Association (NFPA), and the Ameri-

can Society for Heating, Refrigera-

tion and Air Conditioning Engineers

(ASHRAE), and the local code au-

thorities.

C. When cutting or drilling into wall or

ceiling, do not damage electrical wir-

ing and other hidden utilities.

D. To properly exhaust air, be sure to

duct air out side.  Do  not vent exhaust

air into spaces within walls, ceilings,

attics, crawl spaces, or garages.

WARNING:

  

To reduce the risk of

fire, use only metal ductwork.

CAUTION - For General Ventilating

Use Only.  Do Not Use To Exhaust

Hazardous Or Explosive Materials And

Vapors.

INSTALLATION:

1. Remove and discard shipping bracket (attached to motor

mounts and inlet collar).  Check to see if blower wheel turns
freely.  Do not replace top until installation is complete.

2. Provide a square cutout through the roof (or wall) as shown

by the dashed lines, or cut a round hole to fit duct with a
separate hole for electrical conduit as shown by solid lines
in Fig. 1.

3.   Install the remote ventilator with the discharge pointing

down slope as shown in Figures 3 and 4.  Follow standard
roofing procedures. Install the ventilator so the discharge
edge is on top of the shingles and the rear edge is
underneath the shingles.

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

IMPORTANT:

 Save these instructions for the Local Electrical Inspector’s use.

INSTALLER:

 Please leave these Installation Instructions with this unit for the owner.

OWNER:

 Please retain these instructions for future reference.

Recommended for use only over conventional domestic gas and electric ranges, and

use with an approved Bosch Hood.

 SAFETY WARNING: 

Before servic-

ing or cleaning unit, switch power off
at the service panel and lock service
disconnecting means to prevent
power from being switched on acci-
dentally.  When the service discon-
necting means cannot be locked, at-
tach a tag to the service panel to
indicate power has been switched off
for maintenance.

NOTE: 

 The unit must be sealed between the roof (or wall)

and the underside of the flange with roofing mastic to
prevent leaks. For installation on a flat roof, or roofs with
a pitch less than 1-1/2" in 12", install ventilator on the curb
as shown in Fig. 2. Position the curb on flat roofs so that
the discharge (low) end points away from prevailing wind.

4. Connect ventilator to the exhaust system with 8 inch diam.

duct for DHG6003UC and 10" diam. duct for DHG1003UC
and use adjustable elbow to adjust to roof angle. Tape all
joints to prevent air leaks.

5. Connect ducting in the inlet to the ventilator with duct tape.
6. Clearance to combustible material is 0".

For wiring to all approved Bosch products, see Installation

Instructions provided with that product.

INSTALLATION INSTRUCTIONS

ROOF OR WALL VENTILATOR

MODEL DHG6003UC &  DHG1003UC

          Dimension

Model

A

B

C

DHG6003UC 5-11/16"

6-1/8"

9"

DHG1003UC 7-1/4"

6-15/16" 11"

Fig. 1  TOP VIEW   Down Slope of Roof or Wall

(Over)

ONCE INSTALLATION AND WIRING ARE COMPLETE:

1. Turn ventilator on High for 5 minutes to ensure proper

installation.

2. Step to Medium & Low ensuring each speed setting.
3. Turn ventilator off.

Summary of Contents for DHG1003UC

Page 1: ...gles and the rear edge is underneath the shingles PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING IMPORTANT Save these instructions for the Local Electrical Inspector s use INSTALLER Please leave these Installation Instructions with this unit for the owner OWNER Please retain these instructions for future reference Recommended for use only over conventional domestic gas and electric ranges and u...

Page 2: ...1 4 4 WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when flambéing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambé c Clean ventilating fans frequently Grease should...

Page 3: ...ctuer le service ou le nettoyage de l appareil fermer l alimentation au panneau de service et verrouiller Ceci empêchera une mise en circuit accidentelle Si le panneau ne peut être verrouillé apposer une affiche sur le panneau pour indiquer que l alimetation est hors circuit pour l entretien REMARQUE l appareil doit être scellé entre le toit ou le mur et le dessous du rebord avec du mastic pour to...

Page 4: ...appareil sans surveillance lorsqu elle est utilisée à haute température Des débordements peuvent causer de la fumée et des déversements de graisse peuvent causerunincendie Réglerlecontrôleàmoyenoubas pour chauffer les huiles b Toujours mettre en circuit la hotte lors de cuisson à haute température ou pour flamber les aliments i e Crêpes Suzette cerises jubilées boeuf flambé c Nettoyer le ventilate...

Page 5: ...OR LEA TODAS LAS INSTRUCCIONES ANTES DE PROCEDER IMPORTANTE Guarde estas instrucciones para el Inspector Eléctrico Local INSTALADOR Por favor deje estas Instrucciones de Instalación con esta unidad para el propietario PROPIETARIO Por favor guarde estas instrucciones para futuras referencias Se recomienda sólo para el uso encima de estufas domésticas convencionales de gas y eléctricas y con una cam...

Page 6: ...ta Flameado c Limpie los ventiladores frecuentemente No se debe acumular grasa en el ventilador o el filtro d Use ollas de tamaño apropiado Siempre use utensilios apropiados para cocinar de acuerdo al tamaño del elemento superficial Advertencia En caso de un incendio de la estufa no opere el ventilador Cuidado La grasa acumulada en los filtros puede derretirse nuevamente y penetrar la ventilación ...

Page 7: ......

Page 8: ...o change specifications or design without notice Some models are certified for use in Canada BSH is not responsible for products which are transported from the United States for use in Canada Check with your local Canadian distributor or dealer For the most up to date critical installation dimensions by fax use your fax handset and call 702 833 3600 Use code 8030 ...

Reviews: