Prior to installation

Exhaust-air mode

The exhaust air is discharged upwards
through a ventilation shaft or directly
through the outside wall into the open.

D

Exhaust air must not be discharged via

a smoke or exhaust gas flue which is 
already in use or via a shaft which is used
for ventilating rooms in which fireplaces are
located.

Discharge exhaust air in accordance
with official and statutory regulations
(e.g. national building regulations).

Discharge of air into smoke or exhaust air
flues which are not in use requires the
consent of a heating engineer.

D

If the extractor hood is operated in

exhaust-air mode at the same time as a
flue-type heater 

(e.g. gas, oil or solid-fuel

heater, instantaneous water heater, boiler),

ensure that there is an adequate air 
supply 

which the heater requires for 

combustion.

Safe operation is possible provided that the
partial vacuum in the room in which the
heater is installed does not exceed 4 Pa
(0.04 mbar).

This can be achieved if the combustion air
is able to flow through non-lockable 
openings, e.g. in doors, windows and in
conjunction with an air supply/air-intake wall
box or by other technical procedures such
as reciprocal interlocking.

If the air intake is inadequate, there is a
risk of poisoning from combustion gases
which are drawn back into the room.

An air-intake/exhaust-air wall box by itself is
no guarantee that the limiting value will not
be exceeded.

Note: When assessing the overall
requirement, the combined ventilation
system for the entire household must be
taken into consideration. This rule does not
apply to the use of cooking appliances,
such as hobs and gas cookers.

The extractor hood can be used without
restriction in circulating air mode – with an
activated carbon filter.

For exhaust air mode 

a one-way flap

should be installed in the extractor hood
unless already installed in the exhaust air
pipe or wall box.
If a one-way flap is not enclosed with the
extractor hood, you purchase one from
your dealer.

If the exhaust air is conveyed through
the outside wall, 

a telescopic wall box

should be used.

Summary of Contents for DHI 645 F

Page 1: ...40 50 E 0 12 Min DTAG de Gebrauchs und Montageanleitung en Operating and installation instructions fr Mode d emploi et notice de montage nl Gebruiksaanwijzing en montagevoorschrift it Istruzioni d uso e per il montaggio es Instrucciones de uso y de montaje pt Instruções de serviçio e de montagem ...

Page 2: ...2 Abb 1 GAS ELEKTRO GAZ ELECTR KAASU ELETT GASS EL de Seite 03 15 en page 16 28 fr page 29 41 nl pagina 42 54 it pagina 55 67 es página 68 80 pt página 81 93 ...

Page 3: ...orresponding accessory numbers can be found at the end of these operating instructions The extractor hood fan extracts the kitchen vapours which are purified in the grease filter and activated carbon filter and then conveyed back into the kitchen The grease filter absorbs the grease particles in the kitchen vapours The activated carbon filter binds the odorous substances If no activated carbon fil...

Page 4: ...nstructions for Use carefully They contain important information concerning your personal safety as well as on use and care of the appliance Please retain the operating and installation instructions for a subsequent owner Do not use the appliance if damaged The appliance is not intended for use by young children or infirmed persons without supervision Young children should be supervised to ensure ...

Page 5: ...er to stop Sliding switch remains as selected To switch on the extractor again just pull out the filter unit The extractor hood will start at the most recent fan setting Light The light can be switched on at any time even when the appliance is off or the filter drawer is inserted Switching on Take hold of filter drawer handle and pull out the drawer Select the required fan setting Faults If you ha...

Page 6: ...When the grease filter is saturated the indicator starts flashing You should now change the grease filter if you have not already done so Ensure that the grease filters are cleaned at regular intervals approx 1 month Cleaning the metal mesh grease filters The filters can be cleaned in a dishwasher However they may become slightly discoloured Important Do not wash highly saturated metal mesh grease...

Page 7: ...lters Disposing of the old activated carbon filter Activated carbon filters do not contain any pollutants and can be disposed of with domestic refuse Filters and maintenance Activated carbon filter For neutralizing odours in recirculating mode Caution As the filter becomes more and more saturated with grease there is an increased risk of fire and the function of the extractor hood may be impaired ...

Page 8: ...e same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abrasive sponges cleaning agents containing sand soda acid or chloride Aluminium and plastic surfaces Use a soft non linting window cloth or micro fibre cloth Do not use dry cloths Use a mild window cleaning agent Do not use aggressive acidic or caustic cleaners Do not use abrasive...

Page 9: ...will form on the underside of the extractor hood Old appliances are not worthless rubbish Valuable raw materials can be reclaimed by recycling old appliances Before disposing of your old appliance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment by disposi...

Page 10: ...d 4 Pa 0 04 mbar This can be achieved if the combustion air is able to flow through non lockable openings e g in doors windows and in conjunction with an air supply air intake wall box or by other technical procedures such as reciprocal interlocking If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall b...

Page 11: ... backwards Only possible inside tall wall cupboards depending on the size of the exhaust air pipe Make a hole in the rear panel of the wall cupboard cutting out a notch for the power supply cable Exhaust air directed upwards The complete installation set can be obtained from specialist outlets The corresponding accessory numbers can be found at the end of these opera ting instructions 1 Make a hol...

Page 12: ... the template O II further back Ensure that the cupboard is stable both during and after installation even if fitted at the end of a row of kitchen units 1 Mark two attachment points on both the right and left inside faces of the cup board and make holes with a bradawl When you drill 2 mm diameter max 10 mm in depth Use the enclosed template O II to mark the attachment points 2 Screw on both attac...

Page 13: ...Note The extractor hood housing can be clad inside the wall cupboard e g with chipboard If so observe the following The intermediate base must not be placed on the extractor hood housing Never attach cladding to the housing Provide access for customer service Fitting into wall cupboard Check door alignment and readjust if necessary 1 Remove grease filter see Operating instructions 2 Lift the extra...

Page 14: ... reserve the right to construction changes within the context of technical development Weight in kg Attaching the handle moulding A handle moulding must be attached to the filter drawer This handle moulding may be a wooden strip which matches the kitchen units or a handle moulding available as an optional accessory see optional accessories on the back page 1 Using the enclosed template O III mark ...

Page 15: ... saturated See instructions for use section on filter and maintenance Electrical specifications These can be found on the rating plate inside the appliance following removal of the filter frames Before carrying out repairs always isolate the appliance Length of the connection cable 1 30 m If permanent connection is required The extractor hood may only be connected by an electrician registered with...

Page 16: ...95 Notes ...

Page 17: ...Notes 96 ...

Page 18: ...DHZ 4505 434229 1 3 4 2 5 3x Aluminium DHZ 4670 Metall DHZ 4650 DHZ 4600 Absenkrahmen Lowering frame Du cadre d abaissement Befestigingsframe Dei telai per l abbassamento Bastidor para bajar ...

Page 19: ...5750 203 748 Printed in Germany 0704 Es Robert Bosch Hausgeräte GmbH ...

Reviews: