Divar XF
Hardware setup | en
33
Bosch Security Systems
Installation manual
F.01U.135.429 | 2.5 | 2009.08
Figure 4.18
External alarm input and output connector and connection board
Table 4.8
External I/O - 25-pole D-type socket
Signal name
Pin number
Description
Alarm_in_1
1
Alarm input 1
Alarm_in_2
2
Alarm input 2
Alarm_in_3
3
Alarm input 3
Alarm_in_4
4
Alarm input 4
Alarm_in_5
5
Alarm input 5
Alarm_in_6
6
Alarm input 6
Alarm_in_7
7
Alarm input 7
Alarm_in_8
8
Alarm input 8
Alarm_in_9
9
Alarm input 9
Alarm_in_10
10
Alarm input 10
Alarm_in_11
11
Alarm input 11
Alarm_in_12
12
Alarm input 12
Alarm_in_13
13
Alarm input 13
Alarm_in_14
14
Alarm input 14
Alarm_in_15
15
Alarm input 15
Alarm_in_16
16
Alarm input 16
Relay1_A
17
Relay 1 output pole 1
Relay1_B
18
Relay 1 output pole 2
Relay2_A
19
Relay 2 output pole 1
Relay2_B
20
Relay 2 output pole 2
Relay3_A
21
Relay 3 output pole 1
Relay3_B
22
Relay 3 output pole 2
Relay4_A
23
Relay 4 output pole 1
Relay4_B
24
Relay 4 output pole 2
System ground
25
Chassis ground
1A
1B
2A
2B
R
E
L
A
Y
3A
3B
4A
4B
GND
1
2
GND
9
10
3
4
GND
11
12
5
6
GND
13
14
7
8
15
16
IN
IN
IN
IN
13
1
14
25
ALARM I/O
Summary of Contents for DHR-1600A-150A
Page 1: ...Divar XF Digital Hybrid Recorder en Installation manual ...
Page 2: ......
Page 87: ......