52
en | Operating instructions
Divar XF
F.01U.135.429 | 2.5 | 2009.08
Installation manual
Bosch Security Systems
5.10.2
Contact inputs
If a contact input causes an alarm
–
Monitors A and B can display an array of pre-selected cameras.
–
Monitor A: The border around the displayed cameos is red. The alarm icon is displayed in
the corresponding cameo. An alarm status message is displayed.
–
The alarm beeper sounds. The alarm
and the
indicators flash.
–
Controllable cameras might be moved to pre-defined positions.
5.10.3
Motion events
If a motion detection signal causes an event
–
Monitors A and B can switch to display the motion events.
–
The motion icon is displayed in the corresponding cameo. An alarm status message is
displayed.
–
The motion
indicator on the front panel flashes.
5.10.4
Video loss alarm
If the loss of a video signal causes an alarm:
Monitor A or B can be configured to show the video loss signal.
–
One or both monitors can switch to a multiscreen view. The lost camera signal is
displayed as a black cameo with the video loss message. On monitor A, the border
around the camera with the video loss is red. An alarm status message is displayed.
–
The alarm beeper sounds.
–
The video loss
and
indicators flash.
Acknowledging a video loss alarm
Press the acknowledge key
to acknowlede a video loss alarm.
–
The beeper is silent.
–
The video loss
and
indicators are no longer lit.
–
The alarm status message disappears.
–
The last-used view mode is restored.
If the camera with video loss is visible, the black cameo and the video loss message continue
to be displayed as long as there is no video present.
If an alarm is not acknowledged, the beeper switches off after the dwell time but the alarm
still needs to be acknowledged.
If auto-acknowledge is enabled the beeper, and the video loss
and
indicators,
switch off after the dwell time.