66
en | Advanced configuration menu
Divar XF
F.01U.135.429 | 2.5 | 2009.08
Installation manual
Bosch Security Systems
–
If DHCP is disabled, fill in the
IP address
, the
Subnet mask
, the
Default gateway
, and the
DNS Server
address. If required, change the default
HTTP port
(80) to a new value.
–
Restrict the network bandwidth by entering a Mbps value between 0.1 and 100 for the
Bandwidth limit
.
–
The
MAC address
is read only; it shows the MAC address of the DVR.
–
Cable connected
shows the status of the physical network connection.
6.8.2
IP Range
–
Eight IP ranges can be entered to allow access.
–
Enter the same begin and end address to specify a single IP address. Enter different
begin and end addresses to specify an IP address range.
6.8.3
Monitor Streaming
The remote monitor streaming function allows monitor output A and/or B to be streamed
remotely via one or more of the analog video inputs. The main advantage of using this feature
is that multi-screen images can be viewed remotely using just one video stream, thus requiring
only a limited amount of network bandwidth and computer resources.
Each of the analog video inputs can be configured as:
–
Camera input (default).
–
Streaming output A (input is used to stream monitor output A).
–
Streaming output B (input is used to stream monitor output B).
Note:
Disable the recording of a channel used for monitor streaming in the
Recording
tab.
Figure 6.10
Network menu - Monitor streaming