background image

9

Installing the appliance

1.

Hook the appliance from below into the support frame.

Note: 

Ensure that the mains cable is not trapped.

2.

Attach the appliance to the support frame using 2 securing 

screws.

3.

Hook in retaining clip and screw tight.

Connecting the pipes

Note: 

If using an aluminium pipe, smooth the connection area 

beforehand.

Exhaust-air pipe Ø 150 mm (recommended size)

Attach exhaust-air pipe directly to the air-pipe connector 

and seal.

Exhaust-air pipe Ø 120 mm

1.

Attach reducing connector directly to the air-pipe connector.

2.

Attach exhaust air pipe to the reducing connector. 

3.

Seal both joints appropriately.

Electrical connection

ã=

Risk of electric shock!

from damaged connection cable. Do not kink or pinch 
connection cable during installation.
The required connection data can be found on the rating plate 

inside the appliance; to do this, remove the metal-mesh grease 

filter.

Length of the connection cable: approx. 1.30 m

This appliance complies with the EC interference suppression 

regulations.
This appliance may be connected to a correctly installed 

earthed socket only.
Attach the earthed socket preferably inside the flue duct.

The earthed socket should be connected via its own circuit.

If the earthed socket is no longer accessible following 

installation of the appliance, a disconnector must be fitted 

as for a permanent connection. 

If a permanent connection is required, the installation must 

feature an all-pole disconnector (circuit breakers, fuses 

and contactors) with a min. 3 mm contact opening. 

The permanent connection may be installed by an electrician 

only.

[

[

Summary of Contents for DIA09E751B Installation Instructions

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Reviews: