7
Saturation display
When the metal grease filters or activated charcoal filters are
saturated, the corresponding symbol will flash:
■
Metal grease filter:
The F indicator and button 1 light up
■
Activated charcoal filter:
The F indicator and button 3/
G
light up
■
Metal grease filter and activated charcoal filter:
The
F indicator and buttons 1 and 3/
G
light up
Do not wait any longer to clean the metal grease filters or
replace or regenerate the activated charcoal filters.
Removing and installing the filter
The filter must be serviced regularly in order to guarantee
efficient filtration of odours and grease.
Metal grease filter
The metal grease filters must be cleaned every 100 operating
hours or at least every two months.
:
Risk of fire!
Grease deposits in the grease filter may catch fire.
Clean the grease filter at least every 2 months.
Never operate the appliance without the grease filter.
Activated charcoal filters
The activated charcoal filters must be replaced or regenerated
regularly. The saturation indicator on your appliance will tell you
how frequently this needs to be done.
Removing metal grease filter
The metal grease filters filter the grease out of kitchen steam.
To keep them in good working order, the filters should be
cleaned at least every two months.
1.
Pull the filter cover downwards.
Note:
Make sure that the filter cover does not swing down
suddenly.
2.
Open the locking mechanism on the metal grease filter and
remove the filter from the holder.
Notes
■
When you do this, take hold of the metal grease filters from
underneath with your other hand. Make sure that the metal
grease filters do not fall and damage the hob.
■
Fat may collect in the bottom of the filter holder. Hold the
filter holder at an angle to prevent grease from dripping
out.
■
Do not remove the cover plate inside the appliance.
3.
Remove the activated charcoal filters from the metal grease
filters.
4.
Clean the metal grease filters and filter cover.
5.
After removing the filters, clean the inside of the appliance.
Replacing or regenerating the activated charcoal filters
Activated charcoal filters trap the odour-causing compounds in
cooking smells. They are only used for circulating-air mode.
Notes
■
The activated charcoal filters are included with the appliance.
When the activated charcoal filters need to be replaced, they
can be obtained from specialist retailers, from our after-sales
service or from our online shop.
■
Only use genuine replacement filters. This will ensure that the
appliance performs optimally.
1.
Remove the holder on the rear of the metal grease filter and
take out the activated charcoal filter.
2.
Clean the appliance.
3.
Clean the metal grease filters.
4.
Secure the new activated charcoal filter using the holder on
the rear of the metal grease filter.
Regenerating the activated charcoal filter
Note:
The activated charcoal filter can be regenerated up to
four times.
Note:
Odours may develop when regenerating the activated
charcoal filter. Make sure that the room is well ventilated and
open a window if required.
Note:
Regenerated air recirculation filters may be damaged if
they fall or are dropped. The damage is not always visible from
the outside. Dispose of and replace down any regenerated air
recirculation filters that fall or are dropped.
1.
Remove the activated charcoal filter.
2.
Heat the activated charcoal filter for 1 hour at 100 °C in the
oven (preheated) using air recirculation mode.
3.
Allow the activated charcoal filter to cool down.