background image

Summary of Contents for DIP-7280-00N

Page 1: ...DIVAR IP all in one 7000 2U DIP 7280 00N DIP 7284 8HD DIP 7288 8HD DIP 728C 8HD en Installation manual ...

Page 2: ......

Page 3: ...s 19 4 3 1 Separating the sections of the rack rails 20 4 3 2 Installing the inner rails on the chassis 20 4 3 3 Installing the outer rails to the rack 21 4 3 4 Installing the chassis in the rack 21 4 4 Turning on the system 23 5 System setup 24 5 1 Default settings 24 5 2 Prerequisites 24 5 3 Operating modes 24 5 4 Preparing hard drives for video recording 25 5 4 1 Configuring hard drives 25 5 4 ...

Page 4: ...e bay 37 9 5 Identifying a faulty SSD drive 38 9 6 Installing a SSD hard drive into a rear drive bay 38 9 6 1 Removing a hard drive carrier from a rear hard drive bay 38 9 6 2 Installing a hard drive into a rear hard drive carrier 39 9 6 3 Installing a hard drive carrier into a rear hard drive bay 39 9 7 Replacing the DVD ROM drive 40 9 8 Replacing the front port panel 40 9 9 Installing the mother...

Page 5: ...ot wear loose clothing such as neckties and unbuttoned shirt sleeves which can come into contact with electrical circuits or be pulled into a cooling fan Remove any jewelry or metal objects from your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present After accessing the inside o...

Page 6: ... Warning Lithium battery Batteries that have been inserted wrongly can cause an explosion Always replace empty batteries with batteries of the same type or a similar type recommended by the manufacturer Handle used batteries carefully Do not damage the battery in any way A damaged battery may release hazardous materials into the environment Dispose of empty batteries according to the manufacturer ...

Page 7: ...trical shock do not expose this unit to rain or moisture Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electrical shock Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them playing particular attention to cords and ...

Page 8: ...ts Disconnect the power cables before installing or removing any components from the computer including the backplane When disconnecting power you should first turn off the system and then unplug the power cords from all the power supply modules in the system Disconnect the power cable before installing or removing any cables from the backplane When working around exposed electrical circuits anoth...

Page 9: ... ready for use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or printed circuits boards come into contact with your clothing which may retain a charge even if you are wearing a wrist strap Handle a board by its edges only Do not touch its components peripheral chips memory modules or contacts When handling chips or modules avoid touching thei...

Page 10: ...mended by the manufacturer Dispose of the replaced battery in an environmentally friendly way and not with other solid waste Refer all servicing to qualified service personnel Do not place this unit on an unstable stand tripod bracket or mount The unit may fall causing serious injury and or serious damage to the unit Information on sales delivery storage and working life period No restrictions or ...

Page 11: ...rsonnel only It is strongly suggested to place the system in an access control protected area in order to avoid physical manipulation of the system Windows online update functionality or the corresponding monthly roll up patches for offline installation can be used to install OS security updates Limiting local network access to trusted devices is strongly suggested Details are described in the Tec...

Page 12: ... Bosch Security Systems B V 2 About this manual This manual is written for professional system integrators and PC technicians It provides information for the installation and use of the chassis Installation and maintenance should be performed by experienced and qualified technicians only ...

Page 13: ...ured creating an out of the box ready to use video management appliance Access to BVMS After starting the system immediate access to the BVMS application is offered by a customized user interface The ability to use one central user interface for configuration and operation management reduces installation and training requirements and helps to keep ongoing system management costs low 3 1 Chassis co...

Page 14: ...ating I O expansion slots The chassis includes 7 low profile expansion slots Mounting rails The unit can be placed in a rack for secure storage and use To set up your rack follow the instructions included in this manual Control panel The control panel provides a monitoring and control interface LEDs indicate system status and buttons control system power 3 2 Device views The chassis includes a con...

Page 15: ... if separate graphics card has been added to the system 8 1x VGA display output do not use if separate graphics card has been added to the system 9 1x sound card audio inputs and outputs Note Available as optional accessory item not included by default 3 3 Control panel elements The control panel located on the front of the chassis features power buttons and status monitoring LEDs Control panel bu...

Page 16: ...ower failure check for an inoperative power supply Solid blue Local UID has been activated Use this function to locate the unit in a rack environment Blinking blue 300 msec Remote UID has been activated Use this function to locate the unit from a remote location NIC2 This LED indicates network activity on GLAN2 when flashing NIC1 This LED indicates network activity on GLAN1 when flashing HDD This ...

Page 17: ...ll in one 7000 2U System overview en 17 Bosch Security Systems B V Installation manual 2019 08 V1 DOC LED color LED state Description Green On Drive activity Blinking Drive is being accessed Red On Drive failure ...

Page 18: ...ow and ease in servicing Notice This equipment is intended for installation in Restricted Access Location or equivalent Notice This product is not suitable for use with visual display work place devices according to 2 of the German Ordinance for Work with Visual Display Units 4 2 2 Rack precautions Warning To prevent bodily injury when mounting or servicing this unit in a rack you must take specia...

Page 19: ...ent in an environment compatible with the manufacturer s maximum rated ambient temperature Tmra Reduced airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit overloading Consideration ...

Page 20: ...l assembly in the chassis packaging 2 Extend the rail assembly by pulling it outward 3 Press the quick release tab 4 Separate the inner rail extension from the outer rail assembly 4 3 2 Installing the inner rails on the chassis The chassis includes a set of inner rails in two sections inner rails and inner rail extensions The inner rails are pre attached to the chassis and do not interfere with no...

Page 21: ...es 1 2 3 To install the outer rails to the rack 1 Secure the back end of the outer rail to the rack using the screws provided 2 Press the button where the two outer rails are joined to retract the smaller outer rail 3 Hang the hooks of the rails onto the rack holes and if desired use screws to secure the front of the outer rail onto the rack 4 Repeat steps 1 3 for the remaining outer rail Locking ...

Page 22: ... support the chassis during installation Please follow safety recommendations printed on the rails Notice Always install chassis into racks from the bottom up Installing the chassis in a standard rack To install the chassis in a standard rack 1 Extend the outer rails 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pre...

Page 23: ...ssis front and one L shaped bracket to each side of the chassis rear 3 Make sure that the brackets are positioned with just enough space to fit the width of the Telco rack 4 Slide the chassis into the rack and tighten the brackets to the rack 4 4 Turning on the system To turn on the system 1 Plug the power cord from the power supply unit into a high quality power strip that offers protection from ...

Page 24: ...guration Wizard from factory All DIVAR IP systems are preconfigured with a default IP address and with default iSCSI settings IP Address automatically assigned by DHCP fallback IP address 192 168 0 200 Subnet mask automatically assigned by DHCP fallback subnet mask 255 255 255 0 Default user settings for administrator account User BVRAdmin Password WSS4Bosch 5 2 Prerequisites Observe the following...

Page 25: ... Virtual Drive 4 Apply the following settings RAID Level RAID 5 Under Advanced settings Strip Size 64KB Write Policy Write Back Note All other settings remain unchanged 5 Select all hard drives that are part of the RAID group 6 Start the virtual drive initialization 7 Exit the MegaRAID Configuration Utility program 8 Perform a complete system recovery Initial Factory Setup See also Recovering the ...

Page 26: ...estart is finished press CTR ALT DELETE The Windows logon page is displayed 7 Enter the default password WSS4Bosch 8 After entering the password a message is displayed that you must change the password before logging on the first time To confirm click OK 9 Change the password A series of scripts perform important setup tasks This can take several minutes Do not turn off the computer The BVMS defau...

Page 27: ... logon to the administrator account BVRAdmin in order to perform the necessary configuration steps 1 On the BVMS default screen press CTRL ALT DEL 2 Hold SHIFT click Switch User and keep SHIFT pressed for about five seconds 3 Enter administrator user name and password 4 On the Desktop in the Tools folder right click the Disable_BVMS_and_VRM script and then click Run as administrator 5 Add the syst...

Page 28: ...ox is displayed 5 Write down the computer signature or copy and paste it into a text file 6 On a computer with Internet access enter the following URL into your browser https activation boschsecurity com If you do not have an account to access the Bosch License Activation Center either create a new account recommended or click the link to activate a new license without logging on If you create an ...

Page 29: ...con are viewed live To verify recording functionality in the Operator Client 4 Cameras in the Logical Tree with a red dot in the camera s icon are recording To verify playback functionality in the Operator Client 4 The time line moves if the camera is viewed in playback mode To perform further functionalities refer to the BVMS manual available in the online product catalog ...

Page 30: ...ssible from the Internet 6 3 Choosing an appropriate client This chapter describes the ways that allow remote connection to a DIVAR IP system through the internet There are 2 ways to make a remote connection Remote connection with Operator Client page 30 Remote connection with Video Security App page 30 Notice Only use BVMS Operator Client or Video Security App in the version that matches DIVAR IP...

Page 31: ...To install Bosch VMS Enterprise Management Server on a separate server 1 Download the BVMS installer from the product page 2 Copy the BVMS installer to the server that should act as an Enterprise Management Server 3 Double click the installer program then accept the security message 4 In the Welcome dialog box clear all check boxes except Enterprise Management Server and Configuration Client 5 Fol...

Page 32: ...all all hard drives 2 Turn on the system and press Ctrl R when MegaRAID Configuration Utility is displayed on the screen The display appears before Windows starts 3 In the MegaRAID Configuration Utility program select Create Virtual Drive 4 Apply the following settings RAID Level RAID 5 Under Advanced settings Strip Size 64KB Write Policy Write Back Note All other settings remain unchanged 5 Selec...

Page 33: ...on An overheating condition has occurred The system status LED is continuously on Make sure that no cables obstruct the airflow in the system Make sure that all fans are present and operating normally Make sure that the chassis covers are installed Make sure that the heat sinks are installed properly Make sure that the ambient room temperature is not too high ...

Page 34: ...hassis 9 1 Replacement components Although not frequently you may need replacement parts for your system To ensure the highest level of professional service and technical support you must register the systems according to the instructions available as part of the shipment as well as online from the Bosch product catalog 9 2 Removing power from the system Before performing some setup or maintenance...

Page 35: ...off the chassis Notice Except for short periods of time do NOT operate the server without the cover in place The chassis cover must be in place to allow proper airflow and prevent overheating 9 4 Installing a SATA hard drive The unit features hot swappable hard drives which can be removed without turning off the system The hard drives are mounted in hard drive carriers to simplify their installati...

Page 36: ...le 2 Use the handle to pull the hard drive carrier out of the chassis 1 Release button 2 Hard drive carrier handle Notice Except for short periods of time swapping hard drives do not operate the unit with the hard drives removed from the bays 9 4 2 Installing a hard drive into a hard drive carrier To install a hard drive into a hard drive carrier 1 Remove the screws which secure the dummy drive to...

Page 37: ... drives as one of the critical component are carefully selected by Bosch based on available failure rates Hard disk drives not delivered from Bosch are not supported For more information about supported hard disk drives see the datasheet in the Bosch Online Product Catalog at www boschsecurity com 9 4 3 Installing a hard drive carrier into a front drive bay To install a hard drive carrier into a h...

Page 38: ...talling a SSD hard drive into a rear drive bay The unit features two hot swappable hard drives on the rear side which can be removed without powering down the system The hard drives are mounted in hard drive carriers to simplify their installation and removal from the chassis These hard drive carriers also help promote proper airflow for the hard drive bays Procedure To install a SSD hard drive in...

Page 39: ... the four M3 flat head screws included in the hard disk bag of your accessory box Note To secure the hard drive you cannot reuse the screws that are used to secure the dummy drive to the tray Notice Bosch recommends using the respective Bosch hard disk drives The hard disk drives as one of the critical component are carefully selected by Bosch based on available failure rates Hard disk drives not ...

Page 40: ...bles from the motherboard and or backplane 4 Locate the locking tab at the rear on the left when viewed from front of the DVD ROM drive Push the tab toward the drive and push the drive unit out the front of the chassis 5 Insert the new drive unit in the slot until the tab locks in place 6 Reconnect the data and power cables 7 Replace the chassis cover replace the unit in the rack if necessary then...

Page 41: ...es to the backplane and motherboard 9 9 Installing the motherboard Motherboard problems will be handled by trained support people only 9 10 Installing a graphics card To install a graphics card 1 Turn off the system lay the chassis on a flat surface then remove the chassis cover 2 Install the graphics card in the dedicated PCI slot 3 Put back and secure the chassis cover 1 1 Dedicated PCI slot for...

Page 42: ...d 9 12 Installing the air shroud The air shroud does not require screws for its installation Notice If a 16 DIMM 13 68 x 13 motherboard is used it is necessary to use the optional MCP 310 82502 0N air shroud To install the air shroud 1 Make sure that your air shroud matches your chassis model 2 Turn off the system and remove the cover 3 Place the air shroud in the chassis The air shroud fits behin...

Page 43: ... drives or drive trays in the drive bays Use only recommended material 3 Make sure no wires or foreign objects obstruct air flow through the chassis Pull all excess cabling out of the airflow path or use shorter cables The control panel LEDs inform you about system status 9 13 Replacing a system fan Caution Hazardous moving parts Keep away from moving fan blades The fans might still be turning whe...

Page 44: ...pull it completely from the chassis 1 2 1 Release tab 2 Airflow direction indicator 5 Place the new fan into the vacant space in the housing while making sure the arrows on the top of the fan indicating the airflow direction point in the same direction as the arrows on the other fans 6 Reconnect the power cord turn on the system and make sure that the fan is working properly before replacing the c...

Page 45: ...ase tab on the back of the power supply 3 Pull the power supply out using the handle provided 4 Replace the failed power supply with the same model 5 Push the new power supply into the power bay until you hear a click 6 Plug the AC power cord back into the power supply and turn on the unit 9 15 Replacing the power distributor Redundant chassis that are 2U or greater require a power distributor The...

Page 46: ... the Enable_SuperDoctor_5_Service script and then click Run as administrator 5 Double click the SuperDoctor 5 Web icon in the same folder 6 Log on to the web interface using the following default credentials User Name ADMIN Password ADMIN 7 Click the Configuration tab and then click Password Settings and change the default password 8 Click the Configuration tab and then click Alert Configuration 9...

Page 47: ...cked by a 3 year warranty Issues will be handled according to Bosch Service and Support guidelines The storage equipment is shipped with an original manufacturer Service and Support agreement The Bosch Technical Support is the Single Point of Contact in case of failure but the Service and Support obligations are fulfilled by the manufacturer or a partner In order to enable the manufacturer s Servi...

Page 48: ...R IP all in one 7000 2U 2019 08 V1 DOC Installation manual Bosch Security Systems B V 10 Additional documentation and client software For more information software downloads and documentation visit www boschsecurity com and go to the respective product page ...

Page 49: ......

Page 50: ......

Page 51: ......

Page 52: ...Bosch Security Systems B V Torenallee 49 5617 BA Eindhoven Netherlands www boschsecurity com Bosch Security Systems B V 2019 ...

Reviews: