background image

5

The most effective method of removing

vapours produced during cooking is to:

Switch the ventilator ON

as soon as you begin cooking.

Switch the ventilator OFF

a few minutes after you have finished
cooking.

Operating procedure

Switching the fan ON

Press the 

+ button.

Setting the required fan speed:

Press the 

+ button.

The fan speed is increased by one step.

Press the 

– button.

The fan speed is reduced by one step.

Switching the fan OFF:

Press the 

0

button.

Or:

Keep pressing the 

button until the fan

switches off.

Intensive setting:

Maximum power is obtained at the 
intensive setting. It is only required for short
intervals.

Keep pressing the 

+

button until a 

ç

appears in the display.

If the intensive setting is not cancelled by
hand, the fan will automatically switch
back to step 

}

after 10 minutes.

Filters and maintenance

Grease filters:

Metal filters are used to trap the greasy
element of the vapours that develop
during cooking.

The filter mats are made from non-
combustible metal.

Caution:

As the filter becomes more and more 
saturated with grease, not only does the
risk of it catching fire increase but the 
efficiency of the extractor hood can also be
adversely affected.

Important:

By cleaning the metal grease filters at
appropriate intervals, the possibility of them
catching fire as a result of a build-up of heat
such as occurs when deep-fat frying or 
roasting is taking place, is reduced.

Cleaning the metal grease filters:

In normal operation (1 to 2 hours daily),
the metal grease filter must be cleaned
after 8 to 10 weeks.

The filters can be cleaned in a dish-
washer. It is however possible that they
will become slightly discoloured.

The filter must be placed loosely, and
NOT wedged, in the dishwasher.

Important:

Metal filters that are saturated with 
grease should not be washed together
with other dishes etc.

When cleaning the filters by hand, soak
them in hot soapy water first of all.
Then brush the filters clean, rinse them
thoroughly and leave the water to drain off.

Fan OFF

Light

ON / OFF

0

Reduce fan
speed

Fan ON and
increase speed
Intensive setting

Display for fan setting

Lighting:

The light can be switched on at any
time, even though the fan is switched off.

Summary of Contents for DKE 66 . .

Page 1: ...a Operating and installation instructions DKE 66 76 96 Internet http www bosch hausgeraete de Bosch Info Team de Tel 01 80 5 30 40 50 E 0 12 Min DTAG ...

Page 2: ...2 mind 650 mind 550 Abb 1 ELECTRO Fig 1 GAZ ...

Page 3: ...seitige Verriegelung o ä die Verbrennungsluft nachströmen kann Bei nicht ausreichender Zuluft besteht Vergiftungsgefahr durch zurückgesaugte Verbrennungsgase Ein Zuluft Abluftmauerkasten allein stellt die Einhaltung des Grenzwertes nicht sicher Anmerkung Bei der Beurteilung muss immer der gesamte Lüftungsverbund der Wohnung beachtet werden Bei Betrieb von Kochgeräten z B Kochmulde und Gas herd wir...

Page 4: ...or infirmed persons without supervision Young children should be supervised to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user Dispose of packaging materials properly see Installation instructions This...

Page 5: ... As the filter becomes more and more saturated with grease not only does the risk of it catching fire increase but the efficiency of the extractor hood can also be adversely affected Important By cleaning the metal grease filters at appropriate intervals the possibility of them catching fire as a result of a build up of heat such as occurs when deep fat frying or roasting is taking place is reduce...

Page 6: ...moving the filter Warning The halogen bulbs must be switched off and cool 1 Remove the metal filters 2 Press in the lug at the front and remove the activated carbon filter 2 Clean the filters 3 Insert the clean filters back into the hood 3 Insert the metal grease filters Replacing the activated carbon filter During normal operation 1 to 2 hours per day the activated carbon filters should be replac...

Page 7: ...faces Use a mild non abrasive stainless steel cleaner Clean the surface in the same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abrasive sponges cleaning agents containing sand soda acid or chloride Aluminium and plastic surfaces Use a soft non linting window cloth or micro fibre cloth Do not use dry cloths Use a mild window cleani...

Page 8: ...liance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local authority about current means of disposal The extractor hood can be used in ex...

Page 9: ...by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and via the air intake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequa...

Page 10: ... be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adequate supply of fresh air Circulating air mode With activated carbon filter if exhaust air mode is not possible Connecting a l 150 mm exhaust air pipe Mount the pipe directly onto the air outlet on the hood Connecting a l 120 mm e...

Page 11: ...eakers and contactors If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user This extractor hood corresponds to EC regulations concerning RF interference suppression Electrical connection WARNING THIS APPLIANCE MUST BE EARTHED IMPORTANT Fitting a Diff...

Page 12: ...e hob and the extractor hood is maintained 550 mm for an electric hob and 650 mm for a gas hob The bottom edge of the template equates to the lower edge of the extractor hood 4 Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling Insert plugs into the holes so that they are flush with the wall 23 172 455 68 150 mind 550 Elektro mind 650 Gas 216 7 Attach the ...

Page 13: ... grid 09 Connect up the air outlet pipe 10 Connect the hood to the electricity supply 11 Remove the protective film from the two flue ducts Take care not to damage the stainless steel surfaces which are susceptible to scratches etc 12 Insert the upper flue duct slots downwards into the lower flue duct Protect the cover panels from scratches for example by laying the template used for marking the w...

Page 14: ...14 Notes ...

Page 15: ...15 360732 DHZ 5185 1 2 3 4 5 6 2x 10x 2x ...

Page 16: ...5750 207 133 Printed in Germany 0904 Es Robert Bosch Hausgeräte GmbH ...

Reviews: