Operation at the Inverter
3–1
1070 066 028-101 (01.05) GB
3
Operation at the Inverter
3.1
Operator interface
Every DM..8001 (ASM) frequency inverter is equipped with:
D
a keypad with three keys, and
D
a three-digit 7-segment display.
D
an RS 232 interface for connecting a PC, to be operated via the DSS
Diagnostics and Service System.
Using this operator interface, every inverter can be optimized and
commissioned for the specific motor and the machine environment.
It also serves to call up a large number of status information.
H1 – H3
7-segment display for
status and error messages
and parameters
FG
Green LED
for external enable
FGI
Green LED
for internal enable
X
8
FG
FGI
.
.
.
.
.
.
.
.
1
0
X
8
2
0
H
1
H
2
H
3
R
D
TEMP
STA
Keyboard for
parameter input
In the event of a fault, an ’F’ display is shown in the range:
to