5.1.3
Data on the motor rating plate
The motor rating plate data must be entered as a standard.
P04 (A-0-0004)
Rated motor current
I
N
min.
Range
[A]
max.
DM 4K
0.9
0.1
9.5 A
DM 8K
0.9
0.1
9.5 A
DM/DS 15K
1.5
0.5
15.9 A
DM 30K/A
3.1
0.5
31.8 A
DM/DS 45K/A
4.7
0.5
47.7 A
DM 85B
9.5
0.5
95.4 A
DM140D
12.7
0.5
127 A
factory setting
DANGER
Zero speed monitoring and the motor protection function are subject
to the rated motor current.
Please make sure that the data has been entered correctly.
P05 (A-0-0005)
Rated motor power P
N
min.
Range
[kW]
max.
DM 4K
0.2
0.1
5.0 kW
DM 8K
0.2
0.1
5.0 kW
DM/DS 15K
0.3
0.1
8.3 kW
DM 30K/A
0.7
0.1
16.6 kW
DM/DS 45K/A
1.1
0.1
25.0 kW
DM 85B
2.3
0.1
50.0 kW
DM140D
3.1
0.1
66.6 kW
factory setting