DSS User Interface
4–2
1070 066 028-101 (01.05) GB
Configuring the interface
L
Switch on the 24V supply of the system.
L
Switch on the PC. Wait until the operating system has been fully booted and
start the ”DSS” commissioning and service system. The ”Establish connec-
tion” dialog is automatically displayed:
(1)
(2)
(3)
This dialog may also be invoked manually when the connection has been
successfully established:
D
menu sequence EXTRAS
"
INTERFACE SELECT
-or-
D
by clicking on the
command button
"
INTERFACE SELECT
in the DSS basic image.
L
in the ”Primary connection” field (1): V.24 connection (ASM)
L
Set the data in the ”Interface Preferences” field (2) through the following dia-
log:
Click on ”OK” to return to the ”Establish connection” dialog.
L
Clicking on ”OK” in this dialog will cause the DSS to try to establish the de-
sired connection.
D
In the event of a fault, the ”Status” field (3) will contain more information.
Check the connection between the PC and the drive and then click on the
”Retry” command button.
D
If the connection can be established, the DSS will read information from
the drive and then display the DSS basic image.