DSS User Interface
4–7
1070 066 028-101 (01.05) GB
.
Representation of parameters:
In the DSS
At the inverter
Configuration parameters
A-0-0000...A-0-0049
P00...P49
Status displays
A-0-1000 ... A-0-1015
A00 ... A15
3. Press <enter> or click on ”Get” button to read the parameter from the
drive.
If a parameter has been selected which has not been defined for the
drive, an error will be displayed.
4. Modified parameters are transferred back to the drive with ”Set”. First, the
write protection has to be disabled by pressing the boot key (cf. page
5–1). The modified parameters will immediately take effect in the drive
and will remain stored until the next change.
Even though only some parameters have been changed, all parameters
in all parameter lists will be replaced.
During the write process, the 7-segment display on the inverter shows
(serial transmission).
Parameter list
L
In order to display a list of all parameters available in the frequency inverter,
first enter any desired parameter in the ”Ident. number” field and then click on
the ”Export” button offered afterwards.
D
Select a directory from the new window and enter a file name with the ex-
tension ”.asd”.
D
Hitting ”OK” will read all parameters from all 8 parameter lists stored in
the drive. During this process, the 7-segment display on the inverter
shows
(serial transmission).